Omkar A. Ghatpande, K. Corzine, P. Fajri, M. Ferdowsi
{"title":"Multiple reference frame theory for harmonic compensation via doubly fed induction generators","authors":"Omkar A. Ghatpande, K. Corzine, P. Fajri, M. Ferdowsi","doi":"10.1109/PECI.2013.6506035","DOIUrl":null,"url":null,"abstract":"This paper proposes a method of using multiple reference frame theory for harmonic compensation of nonlinear loads using a doubly fed induction generator. The most significant low-order harmonics to be compensated are calculated using a multiple reference frame harmonic observer. This method of measuring and compensating harmonics is accurate straightforward, easily implementable and effective in the mitigation of any harmonic in the system. Simulation results are presented to demonstrate the performance of this proposed method. These results validate the effectiveness of the method in compensating the targeted harmonics in the system. The currents obtained in the fundamental reference frame can be further employed for control of active and reactive power flow.","PeriodicalId":113021,"journal":{"name":"2013 IEEE Power and Energy Conference at Illinois (PECI)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Power and Energy Conference at Illinois (PECI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECI.2013.6506035","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7
Abstract
This paper proposes a method of using multiple reference frame theory for harmonic compensation of nonlinear loads using a doubly fed induction generator. The most significant low-order harmonics to be compensated are calculated using a multiple reference frame harmonic observer. This method of measuring and compensating harmonics is accurate straightforward, easily implementable and effective in the mitigation of any harmonic in the system. Simulation results are presented to demonstrate the performance of this proposed method. These results validate the effectiveness of the method in compensating the targeted harmonics in the system. The currents obtained in the fundamental reference frame can be further employed for control of active and reactive power flow.