Performance of infrared detectors applied in astronomical telescopes

Yongsheng Xiang, Guo Jie, Fangyu Xu, Baicheng Sun, Xiaoxia Gong, Mingguo Fan, Yong-Fang Luo
{"title":"Performance of infrared detectors applied in astronomical telescopes","authors":"Yongsheng Xiang, Guo Jie, Fangyu Xu, Baicheng Sun, Xiaoxia Gong, Mingguo Fan, Yong-Fang Luo","doi":"10.1117/12.2664991","DOIUrl":null,"url":null,"abstract":"This paper describes the significance of infrared astronomy and the development of infrared detectors for astronomical telescope applications. First, the requirements of astronomical observations on infrared focal plane detector indicators such as dark current, readout noise, and image element size are analyzed, and the infrared detector performance parameters of major domestic and foreign astronomical telescopes in recent decades are summarized. Compared with foreign countries, the performance of domestic infrared astronomical telescopes, especially dedicated astronomical infrared detectors, is still very backward. For example, the readout noise is two orders of magnitude higher than the Webb telescope's 5.9e-, and the dark current is four orders of magnitude higher than the Webb telescope's 0.001e− / pixel∙s. Based on the NIR spectroscopic observation requirements of the 1-meter infrared solar telescope at Yunnan Observatory, we developed a low dark current and low noise 640×512 InGaAs NIR focal plane detector module and a dedicated imaging circuit for sunspot imaging and spectroscopic testing. Measurements using the photon curve transfer method showed that the dark current of the InGaAs NIR focal plane camera was as low as 64e−/ pixel∙s, and the average readout noise of the image elements was 25.4e−.Finally, the research direction of special infrared detectors for astronomical observation is discussed, and this paper has implications for the research of next-generation astronomical infrared telescopes in China.","PeriodicalId":258680,"journal":{"name":"Earth and Space From Infrared to Terahertz (ESIT 2022)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Earth and Space From Infrared to Terahertz (ESIT 2022)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2664991","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper describes the significance of infrared astronomy and the development of infrared detectors for astronomical telescope applications. First, the requirements of astronomical observations on infrared focal plane detector indicators such as dark current, readout noise, and image element size are analyzed, and the infrared detector performance parameters of major domestic and foreign astronomical telescopes in recent decades are summarized. Compared with foreign countries, the performance of domestic infrared astronomical telescopes, especially dedicated astronomical infrared detectors, is still very backward. For example, the readout noise is two orders of magnitude higher than the Webb telescope's 5.9e-, and the dark current is four orders of magnitude higher than the Webb telescope's 0.001e− / pixel∙s. Based on the NIR spectroscopic observation requirements of the 1-meter infrared solar telescope at Yunnan Observatory, we developed a low dark current and low noise 640×512 InGaAs NIR focal plane detector module and a dedicated imaging circuit for sunspot imaging and spectroscopic testing. Measurements using the photon curve transfer method showed that the dark current of the InGaAs NIR focal plane camera was as low as 64e−/ pixel∙s, and the average readout noise of the image elements was 25.4e−.Finally, the research direction of special infrared detectors for astronomical observation is discussed, and this paper has implications for the research of next-generation astronomical infrared telescopes in China.
应用于天文望远镜的红外探测器的性能
本文介绍了红外天文学的意义以及红外探测器在天文望远镜中的应用。首先,分析了天文观测对红外焦平面探测器暗电流、读出噪声、像元尺寸等指标的要求,总结了近几十年来国内外主要天文望远镜红外探测器的性能参数。与国外相比,国内红外天文望远镜,特别是专用天文红外探测器的性能还很落后。例如,读出噪声比韦伯望远镜的5.9e-高两个数量级,暗电流比韦伯望远镜的0.001e - /像素∙s高四个数量级。根据云南天文台1米红外太阳望远镜近红外光谱观测需求,研制了低暗电流、低噪声640×512 InGaAs近红外焦平面探测器模块和专用成像电路,用于太阳黑子成像和光谱测试。光子曲线传递法测量表明,InGaAs近红外焦平面相机的暗电流低至64e−/ pixel∙s,图像元素的平均读出噪声为25.4e−。最后,对天文观测专用红外探测器的研究方向进行了探讨,对中国下一代天文红外望远镜的研究具有一定的指导意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信