Proposal of Power Estimation Model of Color BIPV System

Ju-young Shin, S. Ko, W. Shin, H. Hwang, Y. Ju, Gi-Hwan Kang, H. Chang
{"title":"Proposal of Power Estimation Model of Color BIPV System","authors":"Ju-young Shin, S. Ko, W. Shin, H. Hwang, Y. Ju, Gi-Hwan Kang, H. Chang","doi":"10.7836/kses.2021.41.5.001","DOIUrl":null,"url":null,"abstract":"The Korean government is actively promoting mandatory zero energy building (ZEB) implementations to achieve its goal of reducing greenhouse gas emissions. Photovoltaic (PV) technologies are hence being applied in the construction of ZEBs, and building-integrated photovoltaic (BIPV) systems are in the spotlight. BIPV systems are presently being integrated in the building envelopes as parts of the buildings, such as facades, roofs, and windows, to produce on-site clean electricity without requiring additional space. However, the monotonous black-colored BIPV modules are not popular because they affect the aesthetics of the buildings. To mitigate this problem, studies have been conducted on colored BIPV modules to improve the aesthetics of buildings by implementing various colored components. Power estimation is an important part of judging the faults in PV systems. Therefore, this paper proposes a performance estimation model using the characteristics of color BIPV systems based on I-V curve measurements. A color BIPV and meteorological monitoring systems were installed to acquire field survey data. The goal of this study was to verify the superiority of the proposed model by comparison with the power estimated using a simulation tool. The proposed model with high-accuracy power estimations is expected to help diagnose the performance of the BIPV system.","PeriodicalId":276437,"journal":{"name":"Journal of the Korean Solar Energy Society","volume":"117 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Korean Solar Energy Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7836/kses.2021.41.5.001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Korean government is actively promoting mandatory zero energy building (ZEB) implementations to achieve its goal of reducing greenhouse gas emissions. Photovoltaic (PV) technologies are hence being applied in the construction of ZEBs, and building-integrated photovoltaic (BIPV) systems are in the spotlight. BIPV systems are presently being integrated in the building envelopes as parts of the buildings, such as facades, roofs, and windows, to produce on-site clean electricity without requiring additional space. However, the monotonous black-colored BIPV modules are not popular because they affect the aesthetics of the buildings. To mitigate this problem, studies have been conducted on colored BIPV modules to improve the aesthetics of buildings by implementing various colored components. Power estimation is an important part of judging the faults in PV systems. Therefore, this paper proposes a performance estimation model using the characteristics of color BIPV systems based on I-V curve measurements. A color BIPV and meteorological monitoring systems were installed to acquire field survey data. The goal of this study was to verify the superiority of the proposed model by comparison with the power estimated using a simulation tool. The proposed model with high-accuracy power estimations is expected to help diagnose the performance of the BIPV system.
彩色BIPV系统功率估算模型的提出
韩国政府为实现减少温室气体排放的目标,正在积极推进零能耗建筑(ZEB)的强制实施。因此,光伏(PV)技术正在应用于zeb的建设中,建筑集成光伏(BIPV)系统成为人们关注的焦点。BIPV系统目前作为建筑物的一部分被集成在建筑围护结构中,如外墙、屋顶和窗户,在不需要额外空间的情况下产生现场清洁电力。然而,单调的黑色BIPV模块并不受欢迎,因为它们影响了建筑的美学。为了缓解这一问题,已经对彩色BIPV模块进行了研究,通过实施各种彩色组件来改善建筑物的美学。功率估计是光伏系统故障判断的重要组成部分。因此,本文提出了一种基于I-V曲线测量的彩色BIPV系统特性的性能估计模型。安装了彩色BIPV和气象监测系统以获取实地调查数据。本研究的目的是通过与使用仿真工具估计的功率进行比较来验证所提出模型的优越性。该模型具有高精度的功率估计,有望帮助诊断BIPV系统的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信