Full-wave investigation of EFT injection clamp calibration setup

S. Caniggia, Eric Dudenhoeffer, F. Maradei
{"title":"Full-wave investigation of EFT injection clamp calibration setup","authors":"S. Caniggia, Eric Dudenhoeffer, F. Maradei","doi":"10.1109/ISEMC.2010.5711345","DOIUrl":null,"url":null,"abstract":"The paper deals with a full-wave investigation of the capacitive coupling clamp that is used in electrical fast transient (EFT) immunity test to inject disturbances to nominal signals. The analysis is performed by using the software tool MicroWave Studio (MWS) based on the finite integration technique. The model of the injection clamp is validated by comparison with measurements and with the results obtained by SPICE. The full-wave model is used to investigate EFT injection clamp calibration setup, such as that proposed in section “6.4.2 Calibration of the capacitive coupling clamp” of the IEC 61000-4-4 new Edition (i.e., the 3rd).","PeriodicalId":201448,"journal":{"name":"2010 IEEE International Symposium on Electromagnetic Compatibility","volume":"151 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE International Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2010.5711345","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

The paper deals with a full-wave investigation of the capacitive coupling clamp that is used in electrical fast transient (EFT) immunity test to inject disturbances to nominal signals. The analysis is performed by using the software tool MicroWave Studio (MWS) based on the finite integration technique. The model of the injection clamp is validated by comparison with measurements and with the results obtained by SPICE. The full-wave model is used to investigate EFT injection clamp calibration setup, such as that proposed in section “6.4.2 Calibration of the capacitive coupling clamp” of the IEC 61000-4-4 new Edition (i.e., the 3rd).
EFT注射夹校准装置的全波研究
本文研究了用于快速瞬变(EFT)抗扰度测试的电容耦合钳的全波特性,对标称信号注入干扰。利用基于有限积分技术的软件工具MicroWave Studio (MWS)进行分析。通过与测量结果和SPICE计算结果的比较,验证了模型的正确性。全波模型用于研究EFT注入钳校准设置,例如IEC 61000-4-4新版本(即第三版)的“6.4.2电容耦合钳的校准”一节中提出的设置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信