Bi-Directional Nano Grid Design for Organizations with Plug-In Electric Vehicle Charging at Workplace

M. Jawad, M. B. Qureshi, Ahsan Nadeem, S. M. Ali, Noman Shabbir, M. N. Rafiq
{"title":"Bi-Directional Nano Grid Design for Organizations with Plug-In Electric Vehicle Charging at Workplace","authors":"M. Jawad, M. B. Qureshi, Ahsan Nadeem, S. M. Ali, Noman Shabbir, M. N. Rafiq","doi":"10.1109/EIT.2018.8500191","DOIUrl":null,"url":null,"abstract":"Conventionally, the power systems are operating separately as AC or DC grids. Both systems have their advantages and disadvantages; however, if the AC loads need to be connected with the DC grid or DC loads with the AC grid, then DC-AC and AC-DC converters are required that results in conversion losses and an increase in the overall cost. Therefore, a comprehensive solution is the hybrid AC-DC grid in which DC loads relate to the DC grid and AC loads relate to the AC grid and one bi-directional converter joins both AC and DC grids and provides need-based power sharing between them. In future, it will be beneficial to operate big organizations, such as data centers, industry, and telecom exchanges under hybrid AC-DC grids because of the ever-increasing DC load demand and to avoid multiple AC-DC-AC conversion losses. Moreover, in recent times the use of Electric Vehicles (EVs) is increasing rapidly and now workplaces are required to have their own EV fast charging docking stations that adds an extra DC load demand for the organizations. Therefore, by keeping the facts in view, we proposed a hybrid AC-DC nano-grid based distributed power generation and power consumption is proposed as a suitable solution to reduce multiple conversion losses within the organizations. The AC and DC load of the Lahore's central telecom exchange is modeled for the simulations. For hybrid AC-DC nano-grid, a droop controller based bi-directional converter is designed for need-based power sharing between AC and DC nano-grids. The proposed hybrid AC-DC nano grid eliminates the excessive voltage conversion problem of telecom exchanges; provide fuel cell and battery bank-based emergency backup solution along with DC fast charging system for the EVs.","PeriodicalId":188414,"journal":{"name":"2018 IEEE International Conference on Electro/Information Technology (EIT)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE International Conference on Electro/Information Technology (EIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIT.2018.8500191","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Conventionally, the power systems are operating separately as AC or DC grids. Both systems have their advantages and disadvantages; however, if the AC loads need to be connected with the DC grid or DC loads with the AC grid, then DC-AC and AC-DC converters are required that results in conversion losses and an increase in the overall cost. Therefore, a comprehensive solution is the hybrid AC-DC grid in which DC loads relate to the DC grid and AC loads relate to the AC grid and one bi-directional converter joins both AC and DC grids and provides need-based power sharing between them. In future, it will be beneficial to operate big organizations, such as data centers, industry, and telecom exchanges under hybrid AC-DC grids because of the ever-increasing DC load demand and to avoid multiple AC-DC-AC conversion losses. Moreover, in recent times the use of Electric Vehicles (EVs) is increasing rapidly and now workplaces are required to have their own EV fast charging docking stations that adds an extra DC load demand for the organizations. Therefore, by keeping the facts in view, we proposed a hybrid AC-DC nano-grid based distributed power generation and power consumption is proposed as a suitable solution to reduce multiple conversion losses within the organizations. The AC and DC load of the Lahore's central telecom exchange is modeled for the simulations. For hybrid AC-DC nano-grid, a droop controller based bi-directional converter is designed for need-based power sharing between AC and DC nano-grids. The proposed hybrid AC-DC nano grid eliminates the excessive voltage conversion problem of telecom exchanges; provide fuel cell and battery bank-based emergency backup solution along with DC fast charging system for the EVs.
工作场所插电式电动车充电机构的双向纳米网格设计
传统上,电力系统分别作为交流或直流电网运行。这两种制度都有其优点和缺点;但是,如果交流负载需要与直流电网连接,或者直流负载需要与交流电网连接,那么就需要使用DC-AC和AC-DC转换器,这会导致转换损耗和总体成本的增加。因此,一种全面的解决方案是交直流混合电网,其中直流负载与直流电网相关联,交流负载与交流电网相关联,一个双向变换器将交流和直流电网连接起来,并在它们之间提供基于需求的电力共享。未来,数据中心、工业、电信等大型机构在交直流混合电网下运行,将有利于满足日益增长的直流负载需求,避免多次交直流转换损失。此外,近年来电动汽车(EV)的使用正在迅速增加,现在工作场所需要拥有自己的电动汽车快速充电坞,这为组织增加了额外的直流负载需求。因此,考虑到实际情况,我们提出了一种基于交直流混合纳米电网的分布式发电和电力消耗的合适解决方案,以减少组织内部的多次转换损失。模拟了拉合尔中心电信交换机的交流和直流负荷。针对交直流混合纳米电网,设计了一种基于下垂控制器的双向变换器,实现了交直流纳米电网之间基于需求的功率共享。所提出的交直流混合纳米电网消除了电信交换机电压转换过高的问题;为电动汽车提供基于燃料电池和电池组的应急备用解决方案以及直流快速充电系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信