{"title":"Measurements of cerebral arterial oxygen saturation using a fiber-optic pulse oximeter","authors":"J. P. Phillips, R. Langford, Serene H. Chang, K. Maney, P. Kyriacou, Deric P. Jones","doi":"10.1109/IEMBS.2009.5334604","DOIUrl":null,"url":null,"abstract":"This pilot investigation was undertaken to assess the performance of a novel fiber-optic cerebral pulse oximetry system. A fiber-optic probe designed to pass through the lumen of a cranial bolt of the type used to make intracranial pressure measurements was used to obtain optical reflectance signals directly from the brain tissue. Preliminary results from seven patients measured in the operating theatre and ITU are presented. Estimations of cerebral arterial oxygen saturation derived from a frequency domain-based algorithm are compared with pulse oximetry (SpO<inf>2</inf>) and hemoximeter (SaO<inf>2</inf>) blood samples. The mean (±SD) difference between cerebral oxygen saturation (ScaO<inf>2</inf>) and finger SpO<inf>2</inf> (in saturation units) was -7.47(±3.4)%. The mean (±SD) difference between ScaO<inf>2</inf> and blood SaO<inf>2</inf> was -7.37(±2.8)%.","PeriodicalId":332020,"journal":{"name":"2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.2009.5334604","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
This pilot investigation was undertaken to assess the performance of a novel fiber-optic cerebral pulse oximetry system. A fiber-optic probe designed to pass through the lumen of a cranial bolt of the type used to make intracranial pressure measurements was used to obtain optical reflectance signals directly from the brain tissue. Preliminary results from seven patients measured in the operating theatre and ITU are presented. Estimations of cerebral arterial oxygen saturation derived from a frequency domain-based algorithm are compared with pulse oximetry (SpO2) and hemoximeter (SaO2) blood samples. The mean (±SD) difference between cerebral oxygen saturation (ScaO2) and finger SpO2 (in saturation units) was -7.47(±3.4)%. The mean (±SD) difference between ScaO2 and blood SaO2 was -7.37(±2.8)%.