A quantitative analysis of oxygen release due to changes in P50 and venous PO2.

K Rakusan, H Marcinek
{"title":"A quantitative analysis of oxygen release due to changes in P50 and venous PO2.","authors":"K Rakusan,&nbsp;H Marcinek","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>It is almost impossible to estimate the amount of oxygen released from hemoglobin on the basis of the P50 values without calculation, because of the shape of the oxygen dissociation curve. For this reason, we prepared two tables : one indicating the saturation of hemoglobin with oxygen in the venous blood as influenced by venous Po2 and P50 (Table I) and the other, the oxygen release from the arterial blood as influenced by venous Po2 and P50 (Table II). Both tables are based o- the Hill's equation and normal entry data. Values of P50 vary from 20 to 45 torr, while the range for venous Po2 is 5-50 torr. The discussion on possible use of the tables follows.</p>","PeriodicalId":75638,"journal":{"name":"Bulletin de physio-pathologie respiratoire","volume":"11 2","pages":"269-76"},"PeriodicalIF":0.0000,"publicationDate":"1975-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin de physio-pathologie respiratoire","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

It is almost impossible to estimate the amount of oxygen released from hemoglobin on the basis of the P50 values without calculation, because of the shape of the oxygen dissociation curve. For this reason, we prepared two tables : one indicating the saturation of hemoglobin with oxygen in the venous blood as influenced by venous Po2 and P50 (Table I) and the other, the oxygen release from the arterial blood as influenced by venous Po2 and P50 (Table II). Both tables are based o- the Hill's equation and normal entry data. Values of P50 vary from 20 to 45 torr, while the range for venous Po2 is 5-50 torr. The discussion on possible use of the tables follows.

P50和静脉PO2变化引起的氧释放的定量分析。
由于氧解离曲线的形状,在不计算的情况下,几乎不可能根据P50值来估计血红蛋白释放的氧气量。因此,我们准备了两张表:一张表表示静脉血中血红蛋白含氧饱和度受静脉Po2和P50的影响(表1),另一张表表示动脉血中氧释放受静脉Po2和P50的影响(表2)。这两张表均基于Hill’s方程和正常输入数据。P50值为20 ~ 45torr,而静脉Po2值为5 ~ 50torr。下面将讨论这些表格的可能用途。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信