{"title":"Development of static switch with high speed algorithm to fault detection","authors":"C. G. Bianchin, R. Demonti, A. R. de Almeida, M. T. da Silva Filho, C. L. da Silva Pinto","doi":"10.1109/TDC.2012.6281432","DOIUrl":null,"url":null,"abstract":"This paper presents the updated results on research for development of a static switch for operation in medium voltage. It shows the results of the algorithm that detects an outage and enables the digital processing to control the static switch. This algorithm was based on the Clarke and Park transforms. The operation of the switch consists of transferring the power supply from the main source, where an outage occurred, to an alternative power source (backup). The load stays off for a time of milliseconds. A low voltage prototype was built, to allow the evaluation of the algorithm. Then a prototype of the static switch was built in voltage of 13,8kV. The first tests - feeding resistive load - are presented in voltage of 13.8 kV.","PeriodicalId":365141,"journal":{"name":"2012 IEEE International Conference on Industrial Technology","volume":"82 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Conference on Industrial Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TDC.2012.6281432","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents the updated results on research for development of a static switch for operation in medium voltage. It shows the results of the algorithm that detects an outage and enables the digital processing to control the static switch. This algorithm was based on the Clarke and Park transforms. The operation of the switch consists of transferring the power supply from the main source, where an outage occurred, to an alternative power source (backup). The load stays off for a time of milliseconds. A low voltage prototype was built, to allow the evaluation of the algorithm. Then a prototype of the static switch was built in voltage of 13,8kV. The first tests - feeding resistive load - are presented in voltage of 13.8 kV.
静态开关高速故障检测算法的开发
本文介绍了用于中压工作的静态开关的最新研究成果。它显示了算法的结果,检测停电,使数字处理控制静态开关。这个算法是基于克拉克和帕克变换的。开关的操作包括将电源从发生停电的主电源转移到备用电源(备用电源)。负载停止运行几毫秒。建立了一个低压原型,以便对算法进行评估。然后在13.8 kv电压下建立了静态开关的原型。第一次试验是在13.8 kV电压下进行的馈电电阻负载试验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信