AC/DC interactions in multi-infeed HVDC scheme: a case study

R. Nayak, R. Sasmal, Y. Sehgal, Sanjay Mukoo
{"title":"AC/DC interactions in multi-infeed HVDC scheme: a case study","authors":"R. Nayak, R. Sasmal, Y. Sehgal, Sanjay Mukoo","doi":"10.1109/POWERI.2006.1632586","DOIUrl":null,"url":null,"abstract":"In a multi-in feed HVDC configuration wherein two or more HVDC inverters are supplying into a common AC system, the ability of each inverter to influence its own AC bus as well as ability of one inverter to influence another inverter needs to be carefully studied. This paper discusses a three inverter HVDC configuration in a closely linked AC network which shall be coming up in India in near future. The preliminary investigations on the expected interactions between the three inverter terminals are discussed. The paper discusses the interactions due to temporary over voltage, commutation failure performance and AC/DC fault recovery for the multi-in feed HVDC schemes","PeriodicalId":191301,"journal":{"name":"2006 IEEE Power India Conference","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Power India Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/POWERI.2006.1632586","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

In a multi-in feed HVDC configuration wherein two or more HVDC inverters are supplying into a common AC system, the ability of each inverter to influence its own AC bus as well as ability of one inverter to influence another inverter needs to be carefully studied. This paper discusses a three inverter HVDC configuration in a closely linked AC network which shall be coming up in India in near future. The preliminary investigations on the expected interactions between the three inverter terminals are discussed. The paper discusses the interactions due to temporary over voltage, commutation failure performance and AC/DC fault recovery for the multi-in feed HVDC schemes
多馈入HVDC方案中的交直流相互作用:一个案例研究
在多路馈电HVDC配置中,两个或多个HVDC逆变器向公共交流系统供电,需要仔细研究每个逆变器影响其自身交流母线的能力以及一个逆变器影响另一个逆变器的能力。本文讨论了将在不久的将来在印度出现的一个紧密连接的交流网络中的三逆变器高压直流配置。讨论了三个逆变器终端之间预期相互作用的初步研究。本文讨论了多路馈电直流方案的暂过电压相互作用、换相失效性能和交直流故障恢复问题
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信