{"title":"A new method for uninterrupted operation of wind turbines equipped with DFIGs during grid faults using FCL","authors":"M. Fazli, N. Talebi","doi":"10.1109/EEEIC.2010.5490024","DOIUrl":null,"url":null,"abstract":"The main issue of wind turbines that equipped with doubly fed induction generators (DFIGs) is the grid faults or low voltage ride through capability. In this paper, a new solution for uninterrupted operation of wind turbine driving a DFIG has been proposed during fault condition in the grid. A fault current limiter (FCL) is placed in series with the rotor circuit. During fault condition FCL enters a huge solenoid in the rotor circuit to inhabit increasing of current in the rotor circuit. When the fault is cleared the FCL bypasses the solenoid. A static synchronous compensator (STATCOM) has been applied for supplying required reactive power in faults and steady states. Capability and modeling accuracy of the proposed method confirmed with simulating a sample power system in PSCAD/EMTDC software.","PeriodicalId":197298,"journal":{"name":"2010 9th International Conference on Environment and Electrical Engineering","volume":"196 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 9th International Conference on Environment and Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEEIC.2010.5490024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18
Abstract
The main issue of wind turbines that equipped with doubly fed induction generators (DFIGs) is the grid faults or low voltage ride through capability. In this paper, a new solution for uninterrupted operation of wind turbine driving a DFIG has been proposed during fault condition in the grid. A fault current limiter (FCL) is placed in series with the rotor circuit. During fault condition FCL enters a huge solenoid in the rotor circuit to inhabit increasing of current in the rotor circuit. When the fault is cleared the FCL bypasses the solenoid. A static synchronous compensator (STATCOM) has been applied for supplying required reactive power in faults and steady states. Capability and modeling accuracy of the proposed method confirmed with simulating a sample power system in PSCAD/EMTDC software.