{"title":"On Dynamical (B/Gd) Neutron Cancer Therapy by Accelerator Based Two Opposing Neutron Beams","authors":"N. Haidar","doi":"10.4172/2155-9619.1000345","DOIUrl":null,"url":null,"abstract":"The work reported in this paper studies the problem of irradiation of a single cancerous region in a (B/Gd) NCT setup by two opposing modulated one-speed neutron beams. The beams, which may have different pulse shapes, have different modulation frequencies and a variable relative time advance. These different frequencies and time advance are shown to be employable as three control variables in the formulation of a nonlinear optimization process that maximizes the therapeutic utility index and the ballistic index for this kind of dynamical (B/Gd)NCT.","PeriodicalId":302578,"journal":{"name":"Journal of Nuclear Medicine and Radiation Therapy","volume":"69 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nuclear Medicine and Radiation Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2155-9619.1000345","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
The work reported in this paper studies the problem of irradiation of a single cancerous region in a (B/Gd) NCT setup by two opposing modulated one-speed neutron beams. The beams, which may have different pulse shapes, have different modulation frequencies and a variable relative time advance. These different frequencies and time advance are shown to be employable as three control variables in the formulation of a nonlinear optimization process that maximizes the therapeutic utility index and the ballistic index for this kind of dynamical (B/Gd)NCT.