{"title":"A novel voltage control for active shunt power filters","authors":"P. Zanchetta, M. Sumner, B. Palethorpe, A. Lecci, A. Dell'Aquila","doi":"10.1109/ISIE.2002.1025857","DOIUrl":null,"url":null,"abstract":"In this paper a new voltage control for shunt active power filters is presented. The proposed system is able to compensate one harmonic current flowing into the electric network without the need for measuring the non linear load current, or supply line current. Only the line voltage is measured. The developed control sets, by means of a genetic algorithm, the suitable values of amplitude and phase of the harmonic compensating current used as reference signal for a carrier modulated PWM voltage source inverter. Simulation tests carried out using Simulink and the Power System Blockset, show the reliability and the effectiveness of the compensation action.","PeriodicalId":330283,"journal":{"name":"Industrial Electronics, 2002. ISIE 2002. Proceedings of the 2002 IEEE International Symposium on","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Industrial Electronics, 2002. ISIE 2002. Proceedings of the 2002 IEEE International Symposium on","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2002.1025857","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In this paper a new voltage control for shunt active power filters is presented. The proposed system is able to compensate one harmonic current flowing into the electric network without the need for measuring the non linear load current, or supply line current. Only the line voltage is measured. The developed control sets, by means of a genetic algorithm, the suitable values of amplitude and phase of the harmonic compensating current used as reference signal for a carrier modulated PWM voltage source inverter. Simulation tests carried out using Simulink and the Power System Blockset, show the reliability and the effectiveness of the compensation action.
一种新型有源并联电源滤波器电压控制方法
本文提出了一种新的并联型有源电力滤波器电压控制方法。该系统能够补偿流入电网的一次谐波电流,而不需要测量非线性负载电流或供电线路电流。只测量线路电压。利用遗传算法确定谐波补偿电流的合适幅值和相位值,作为载波调制PWM电压源逆变器的参考信号。利用Simulink和Power System Blockset进行了仿真试验,验证了该补偿措施的可靠性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信