Hardware Accelerated Inverse Kinematics for Low Power Surgical Manipulators

Oleksii M. Tkachenko, K. Song
{"title":"Hardware Accelerated Inverse Kinematics for Low Power Surgical Manipulators","authors":"Oleksii M. Tkachenko, K. Song","doi":"10.1109/ARIS50834.2020.9205769","DOIUrl":null,"url":null,"abstract":"Robotic minimally invasive surgery (MIS) is performed via small incisions and so lessens wound healing time, associated pain and risk of infection. We refactor the control pipeline and accelerate the most time-consuming stage- inverse kinematics (IK) calculation for robot assisted MIS. Field programmable gate array (FPGA) technology is used to develop a low power hardware IK accelerator. The set of optimization techniques reduces the design’s size so it can fit onto the real hardware. Accelerator executes IK in approximately 30 microseconds. System architecture runs on a heterogeneous CPUFPGA platform. Single and multi-point architectures are developed, where multi-point architecture overcomes communication overhead between platforms and allows achieving a higher output rate. Implementation is tested for 16, 24 and 32-bit fixed-point numbers, with an average computation error of 0.07 millimeters for 32-bit architecture. Experimental results validate and verify the proposed solution.","PeriodicalId":423389,"journal":{"name":"2020 International Conference on Advanced Robotics and Intelligent Systems (ARIS)","volume":"116 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Conference on Advanced Robotics and Intelligent Systems (ARIS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ARIS50834.2020.9205769","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Robotic minimally invasive surgery (MIS) is performed via small incisions and so lessens wound healing time, associated pain and risk of infection. We refactor the control pipeline and accelerate the most time-consuming stage- inverse kinematics (IK) calculation for robot assisted MIS. Field programmable gate array (FPGA) technology is used to develop a low power hardware IK accelerator. The set of optimization techniques reduces the design’s size so it can fit onto the real hardware. Accelerator executes IK in approximately 30 microseconds. System architecture runs on a heterogeneous CPUFPGA platform. Single and multi-point architectures are developed, where multi-point architecture overcomes communication overhead between platforms and allows achieving a higher output rate. Implementation is tested for 16, 24 and 32-bit fixed-point numbers, with an average computation error of 0.07 millimeters for 32-bit architecture. Experimental results validate and verify the proposed solution.
低功率手术机械臂的硬件加速逆运动学
机器人微创手术(MIS)通过小切口进行,因此减少了伤口愈合时间,相关疼痛和感染风险。我们重构了机器人辅助管理信息系统的控制管道,并加速了最耗时的阶段-逆运动学(IK)计算。采用现场可编程门阵列(FPGA)技术开发了一种低功耗硬件IK加速器。这组优化技术减少了设计的尺寸,使其能够适应实际的硬件。加速器在大约30微秒内执行IK。系统架构运行在异构CPUFPGA平台上。开发了单点和多点架构,其中多点架构克服了平台间的通信开销,实现了更高的输出速率。对16位、24位和32位定点数的实现进行了测试,32位架构的平均计算误差为0.07毫米。实验结果验证了所提出的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信