{"title":"[Determination of iron with CentrifiChem System].","authors":"H G Eisenwiener","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The determination of iron was adapted to the CentrifiChem System. The iron bound to transferrin is freed with a detergent, reduced to Fe++ with sodium dithionite, and determined with bathophenanthroline disulphonate. The operation consists of one run for the blank value and one analytical run. Although the actual reaction time is extremely short, a reaction time of 8--10 min is recommended for both the blank value and the analysis. This ensures adequate clearing during centrifugation under the influence of Teepol. 2 times 100 mul serum are required, and 80 determinations per hour are possible.</p>","PeriodicalId":23822,"journal":{"name":"Zeitschrift fur klinische Chemie und klinische Biochemie","volume":"13 1","pages":"21-4"},"PeriodicalIF":0.0000,"publicationDate":"1975-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeitschrift fur klinische Chemie und klinische Biochemie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The determination of iron was adapted to the CentrifiChem System. The iron bound to transferrin is freed with a detergent, reduced to Fe++ with sodium dithionite, and determined with bathophenanthroline disulphonate. The operation consists of one run for the blank value and one analytical run. Although the actual reaction time is extremely short, a reaction time of 8--10 min is recommended for both the blank value and the analysis. This ensures adequate clearing during centrifugation under the influence of Teepol. 2 times 100 mul serum are required, and 80 determinations per hour are possible.

[CentrifiChem系统测定铁]。
铁的测定适用于CentrifiChem系统。与转铁蛋白结合的铁用洗涤剂释放,用二亚硫酸钠还原为铁++,用二磺酸邻菲罗啉测定。该操作包括一次空白值运行和一次分析运行。虽然实际反应时间极短,但空白值和分析的反应时间建议为8- 10分钟。这确保了在Teepol的影响下离心过程中有足够的清除。需要2倍100多份血清,每小时可以测定80次。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信