L. Tanklevskiy, A. Tarantsev, A. Bondar, I. D. Balabanov
{"title":"Aspects of implementation of automatic fire containment systems","authors":"L. Tanklevskiy, A. Tarantsev, A. Bondar, I. D. Balabanov","doi":"10.22227/0869-7493.2022.31.05.43-53","DOIUrl":null,"url":null,"abstract":"Introduction. The authors specify the areas of application of automatic fire-prevention systems and the objects that they protect; they also substantiate the main principles of their design and development. Rational hydraulic sprinkler arrangement patterns are designed for automatic water fire-containment systems to be installed in large and small premises, depending on the thermal loading of structures.Goal and objectives. Development of recommendations on the use of automatic fire-containment systems and the objects that they protect.Materials and methods. Fire development patterns were subjected to theoretical and experimental research conducted during variable intensity water supply.Results and their discussion. As a result of this research, general engineering requirements for automatic water fire-containment systems and their testing methods were first developed.Conclusions. The first edition of GOST (All-Russian State Standard) “Automatic water fire-containment systems. General engineering requirements. Testing methods” were addressed to the organizations concerned with this area of knowledge; their opinions and suggestions were contributed to another approved edition of this GOST (All-Russian State Standard).","PeriodicalId":169739,"journal":{"name":"Pozharovzryvobezopasnost/Fire and Explosion Safety","volume":"87 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pozharovzryvobezopasnost/Fire and Explosion Safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22227/0869-7493.2022.31.05.43-53","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Introduction. The authors specify the areas of application of automatic fire-prevention systems and the objects that they protect; they also substantiate the main principles of their design and development. Rational hydraulic sprinkler arrangement patterns are designed for automatic water fire-containment systems to be installed in large and small premises, depending on the thermal loading of structures.Goal and objectives. Development of recommendations on the use of automatic fire-containment systems and the objects that they protect.Materials and methods. Fire development patterns were subjected to theoretical and experimental research conducted during variable intensity water supply.Results and their discussion. As a result of this research, general engineering requirements for automatic water fire-containment systems and their testing methods were first developed.Conclusions. The first edition of GOST (All-Russian State Standard) “Automatic water fire-containment systems. General engineering requirements. Testing methods” were addressed to the organizations concerned with this area of knowledge; their opinions and suggestions were contributed to another approved edition of this GOST (All-Russian State Standard).