Actuator fault detection identification and isolation via high-gain observer for an olive oil waste esterification in a Semi Continuous Stirred Tank Reactor
Amira Abdelkader, Moez Boussada, K. Fiaty, H. Hammouri, A. S. Nouri
{"title":"Actuator fault detection identification and isolation via high-gain observer for an olive oil waste esterification in a Semi Continuous Stirred Tank Reactor","authors":"Amira Abdelkader, Moez Boussada, K. Fiaty, H. Hammouri, A. S. Nouri","doi":"10.1109/STA.2015.7505232","DOIUrl":null,"url":null,"abstract":"In this study, we have developed a method of diagnosis based on high gain observers, for detecting faults of the actuators in a semi continuous chemical reactor. This algorithm has the advantage of detecting multiple faults simultaneously. The observer is constructed from a sub-model, one needs two observers which related to the number of actuator. The signals used in our study derived from a real system. This diagnostic strategy has two levels, to detect and identify defects actuators, feed rate and the warming system in order to improve the reaction rate.","PeriodicalId":128530,"journal":{"name":"2015 16th International Conference on Sciences and Techniques of Automatic Control and Computer Engineering (STA)","volume":"107 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 16th International Conference on Sciences and Techniques of Automatic Control and Computer Engineering (STA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/STA.2015.7505232","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
In this study, we have developed a method of diagnosis based on high gain observers, for detecting faults of the actuators in a semi continuous chemical reactor. This algorithm has the advantage of detecting multiple faults simultaneously. The observer is constructed from a sub-model, one needs two observers which related to the number of actuator. The signals used in our study derived from a real system. This diagnostic strategy has two levels, to detect and identify defects actuators, feed rate and the warming system in order to improve the reaction rate.