{"title":"Trilateral comparison of a planar thin-film thermal AC voltage standard up to 1 MHz","authors":"M. Kampik, M. Grzenik, T. Lippert, B. Trinchera","doi":"10.1109/CPEM.2016.7540532","DOIUrl":null,"url":null,"abstract":"The paper present results of trilateral comparison of a travelling AC voltage standard with PTB/IPHT planar thin-film thermal converter. The AC-DC voltage transfer difference of the standard was measured at 1 V and selected frequencies from 20 Hz to 1 MHz against primary thermal AC voltage standards at SUT, INRIM and Trescal.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2016.7540532","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
The paper present results of trilateral comparison of a travelling AC voltage standard with PTB/IPHT planar thin-film thermal converter. The AC-DC voltage transfer difference of the standard was measured at 1 V and selected frequencies from 20 Hz to 1 MHz against primary thermal AC voltage standards at SUT, INRIM and Trescal.