M. Tsukuda, Daisuke Yuki, H. Tomonaga, Hyoungseop Kim, I. Omura
{"title":"Current distribution based power module screening by new normal/abnormal classification method with image processing","authors":"M. Tsukuda, Daisuke Yuki, H. Tomonaga, Hyoungseop Kim, I. Omura","doi":"10.23919/ISPSD.2017.7988970","DOIUrl":null,"url":null,"abstract":"We developed a screening equipment for ceramic substrate level power module of IGBT. The equipment realizes a new screening test with current distribution. The equipment acquires magnetic field signals over bonding wires and finally classifies to normal/abnormal module automatically. We established statistics based normal/abnormal classification with image processing. It is expected to be applied for screening in a production line and analysis to prevent the failure of power modules.","PeriodicalId":202561,"journal":{"name":"2017 29th International Symposium on Power Semiconductor Devices and IC's (ISPSD)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 29th International Symposium on Power Semiconductor Devices and IC's (ISPSD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/ISPSD.2017.7988970","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
We developed a screening equipment for ceramic substrate level power module of IGBT. The equipment realizes a new screening test with current distribution. The equipment acquires magnetic field signals over bonding wires and finally classifies to normal/abnormal module automatically. We established statistics based normal/abnormal classification with image processing. It is expected to be applied for screening in a production line and analysis to prevent the failure of power modules.