Fully Guided Synthetic Osteochondral Resurfacing of a Large Stifle OCD Lesion Using a Patient-Specific Implant and Drill Guides

VCOT Open Pub Date : 2022-06-09 DOI:10.1055/s-0042-1758680
Jasmine Moser, G. Haimel, Karen Barker-Benfield, Katharina Leschnik, P. Böttcher
{"title":"Fully Guided Synthetic Osteochondral Resurfacing of a Large Stifle OCD Lesion Using a Patient-Specific Implant and Drill Guides","authors":"Jasmine Moser, G. Haimel, Karen Barker-Benfield, Katharina Leschnik, P. Böttcher","doi":"10.1055/s-0042-1758680","DOIUrl":null,"url":null,"abstract":"Abstract Synthetic anatomical reconstruction of extensive, oval osteochondrosis dissecans (OCD) defects remains a challenge due to the ‘one shape fits all’ design of commercial round implants. This is further complicated by the inherent inaccuracy of free-hand implant positioning procedures. A 6-month-old German Shepherd presented with a 15 × 7.8 × 4.3 mm OCD defect at the lateral femoral condyle. A synthetic patient-specific implant (PSI) was designed, using the contralateral unaffected condyle as a template. Reaming of the implant bed was fully guided using a set of three-dimensional-printed drill guides. The implant, consisting of a titanium base and a polycarbonate urethane bearing surface, was press-fit into place. Temporary meniscal release of the cranial meniscal horn was repaired, followed by routine closure and postoperative care. The combination of PSI and matching drill guides resulted in an accurate restoration of the normal joint surface at the former defect area. At 6-week and 18-month follow-ups, mild joint effusion, unexpected soft tissue mineralization and a small joint mouse were present. No other complications were encountered, and the dog was clinically lameness-free. At 6 weeks and 6 months, computerized gait analysis documented increased loading of the affected limb from 36% preoperatively to 42 and 40%, on follow-up, respectively. Body weight distribution between both hindlimbs was nearly equal at the 6-month control with 1% difference in loading. Osteochondral resurfacing using a PSI appears to be a promising treatment option for large stifle OCD lesions in which other treatment modalities may not be eligible.","PeriodicalId":443672,"journal":{"name":"VCOT Open","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"VCOT Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0042-1758680","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Synthetic anatomical reconstruction of extensive, oval osteochondrosis dissecans (OCD) defects remains a challenge due to the ‘one shape fits all’ design of commercial round implants. This is further complicated by the inherent inaccuracy of free-hand implant positioning procedures. A 6-month-old German Shepherd presented with a 15 × 7.8 × 4.3 mm OCD defect at the lateral femoral condyle. A synthetic patient-specific implant (PSI) was designed, using the contralateral unaffected condyle as a template. Reaming of the implant bed was fully guided using a set of three-dimensional-printed drill guides. The implant, consisting of a titanium base and a polycarbonate urethane bearing surface, was press-fit into place. Temporary meniscal release of the cranial meniscal horn was repaired, followed by routine closure and postoperative care. The combination of PSI and matching drill guides resulted in an accurate restoration of the normal joint surface at the former defect area. At 6-week and 18-month follow-ups, mild joint effusion, unexpected soft tissue mineralization and a small joint mouse were present. No other complications were encountered, and the dog was clinically lameness-free. At 6 weeks and 6 months, computerized gait analysis documented increased loading of the affected limb from 36% preoperatively to 42 and 40%, on follow-up, respectively. Body weight distribution between both hindlimbs was nearly equal at the 6-month control with 1% difference in loading. Osteochondral resurfacing using a PSI appears to be a promising treatment option for large stifle OCD lesions in which other treatment modalities may not be eligible.
使用患者特异性植入物和钻头引导的全引导人工骨软骨置换大膝关节OCD病变
摘要:由于商业圆形植入物的“一种形状适合所有人”的设计,广泛的椭圆形解剖性骨软骨病(OCD)缺陷的合成解剖重建仍然是一个挑战。徒手植入物定位程序固有的不准确性使情况进一步复杂化。一只6个月大的德国牧羊犬在股骨外侧髁处出现15 × 7.8 × 4.3 mm的OCD缺损。使用对侧未受影响的髁作为模板,设计了一种合成的患者特异性种植体(PSI)。使用一套三维打印钻头导轨完全引导植入床的扩孔。植入物由钛基和聚碳酸酯氨基甲酸酯承载表面组成,被压入适当的位置。修复临时半月板释放的颅半月板角,随后进行常规闭合和术后护理。PSI和匹配的钻头导向的结合导致了在原缺陷区域正常连接表面的精确恢复。在6周和18个月的随访中,出现轻度关节积液,意想不到的软组织矿化和小关节小鼠。无其他并发症,临床无跛行。在6周和6个月时,计算机步态分析记录了受影响肢体的负荷分别从术前的36%增加到随访时的42%和40%。在6个月的对照中,两后肢之间的体重分布几乎相等,负荷差异为1%。在其他治疗方式不适合的情况下,采用PSI进行骨软骨表面置换似乎是一种很有前途的治疗选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信