{"title":"Design and performance evaluation of next generation clutch control valve","authors":"M. Erhard, J. Schneider, Jan Stein","doi":"10.25368/2020.99","DOIUrl":null,"url":null,"abstract":"Pressure reducing valves perform various control tasks in mobile machines. In many cases contamination sensitive environments require pilot-operated valves, because of its more robust performance. On the other hand, dynamic valve behavior can be critically in certain applications. Overcoming the restrictions resulting from stand-alone test rig attempts, suitable simulation principles are nowadays the state of art in valve design. Unsuitable model approaches and missing consideration of the application may result in wrong design decisions. This paper discusses two important modeling issues, in particular the solenoid and spool leakage behavior, in combination with the connected system under control, a pressure-actuated clutch. It is shown, that even for standard proportional valves a site of installation decides on success or failure of an already used design variant.","PeriodicalId":254837,"journal":{"name":"Volume 3 - Conference","volume":"429 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 3 - Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25368/2020.99","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Pressure reducing valves perform various control tasks in mobile machines. In many cases contamination sensitive environments require pilot-operated valves, because of its more robust performance. On the other hand, dynamic valve behavior can be critically in certain applications. Overcoming the restrictions resulting from stand-alone test rig attempts, suitable simulation principles are nowadays the state of art in valve design. Unsuitable model approaches and missing consideration of the application may result in wrong design decisions. This paper discusses two important modeling issues, in particular the solenoid and spool leakage behavior, in combination with the connected system under control, a pressure-actuated clutch. It is shown, that even for standard proportional valves a site of installation decides on success or failure of an already used design variant.