Reliability and validity of the Body Awareness Rating Scale (BARS), an observational assessment tool of movement quality

L. H. Skjaerven, G. Gard, M. Sundal, L. Strand
{"title":"Reliability and validity of the Body Awareness Rating Scale (BARS), an observational assessment tool of movement quality","authors":"L. H. Skjaerven, G. Gard, M. Sundal, L. Strand","doi":"10.3109/21679169.2014.992470","DOIUrl":null,"url":null,"abstract":"Abstract Movement quality assessed by the Body Awareness Rating Scale (BARS) is used as an indicator of health and self-efficacy in patients with long-lasting musculoskeletal and mental health problems. The objective of the study was to examine reliability and construct validity of the movement quality scale. 25 patients and 25 healthy persons were included. Internal consistency was examined by Cronbach's α, reliability by intraclass correlation coefficient (ICCagreement) and measurement error reported by standard error of measurement (SEM) and smallest detectable change (SDC). Construct validity was examined by testing hypotheses of moderate association between the observational scale and the self-report Short-Form Health Survey (SF-36) subscales and the General Perceived Self-Efficacy Scale (GPSES). A hypothesis about the difference in scores between groups being expected to differ in health states was tested. Internal consistency (α) was 0.92. Inter-tester reliability was ICC = 0.99 and SEM = 0.8. The test–retest reliability was ICC = 0.96 and SEM = 1.4, implying that improvement should be above 3.3 (SDC) to claim a treatment effect. BARS was moderately correlated (0.30 ≤ rs < 0.60) with most SF-36 subscales and GPSES. The patients demonstrated less movement quality than healthy persons. Evidence was provided of high internal consistency and reliability in qualified testers. Construct validity was indicated, as BARS reflected various aspects of health and self-efficacy.","PeriodicalId":186472,"journal":{"name":"The European Journal of Physiotherapy","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"24","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The European Journal of Physiotherapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/21679169.2014.992470","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 24

Abstract

Abstract Movement quality assessed by the Body Awareness Rating Scale (BARS) is used as an indicator of health and self-efficacy in patients with long-lasting musculoskeletal and mental health problems. The objective of the study was to examine reliability and construct validity of the movement quality scale. 25 patients and 25 healthy persons were included. Internal consistency was examined by Cronbach's α, reliability by intraclass correlation coefficient (ICCagreement) and measurement error reported by standard error of measurement (SEM) and smallest detectable change (SDC). Construct validity was examined by testing hypotheses of moderate association between the observational scale and the self-report Short-Form Health Survey (SF-36) subscales and the General Perceived Self-Efficacy Scale (GPSES). A hypothesis about the difference in scores between groups being expected to differ in health states was tested. Internal consistency (α) was 0.92. Inter-tester reliability was ICC = 0.99 and SEM = 0.8. The test–retest reliability was ICC = 0.96 and SEM = 1.4, implying that improvement should be above 3.3 (SDC) to claim a treatment effect. BARS was moderately correlated (0.30 ≤ rs < 0.60) with most SF-36 subscales and GPSES. The patients demonstrated less movement quality than healthy persons. Evidence was provided of high internal consistency and reliability in qualified testers. Construct validity was indicated, as BARS reflected various aspects of health and self-efficacy.
运动质量观察性评估工具——身体意识评定量表(BARS)的信度和效度
摘要采用身体意识评定量表(BARS)评估运动质量,作为长期存在肌肉骨骼和心理健康问题患者健康和自我效能的一项指标。本研究的目的是检验运动素质量表的信度和编制效度。纳入25例患者和25例健康人。内部一致性采用Cronbach’s α检验,信度采用类内相关系数(ICCagreement)检验,测量误差采用测量标准误差(SEM)和最小可检测变化(SDC)报告。通过检验观察量表与自我报告简短健康调查(SF-36)子量表和一般自我效能感量表(GPSES)之间存在适度关联的假设来检验结构效度。一个关于健康状况不同的群体之间得分差异的假设得到了检验。内部一致性(α)为0.92。测者间信度ICC = 0.99, SEM = 0.8。重测信度为ICC = 0.96, SEM = 1.4,表明改善应高于3.3 (SDC)才能声称治疗效果。BARS与大多数SF-36分量表和GPSES呈正相关(0.30≤rs < 0.60)。患者的运动质量低于健康人。证据提供了高内部一致性和可靠性在合格的测试。由于BARS反映了健康和自我效能的各个方面,因此表明了结构效度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信