Control methods for active power filters with minimum measurement requirements

D. Casadei, G. Grandi, U. Reggiani, C. Rossi
{"title":"Control methods for active power filters with minimum measurement requirements","authors":"D. Casadei, G. Grandi, U. Reggiani, C. Rossi","doi":"10.1109/APEC.1999.750514","DOIUrl":null,"url":null,"abstract":"Two shunt active power filter configurations are analyzed in this paper in order to define new control methods characterized by simple control algorithms and minimum voltage and current transducer requirements. The transfer functions for the two control schemes are determined and analyzed to emphasize the active filter behavior in both steady-state and transient conditions. The performance obtained by the proposed control schemes is similar to that of standard solutions. The experimental results substantially confirm the numerical results obtained by Simulink of Matlab.","PeriodicalId":287192,"journal":{"name":"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"26","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"APEC '99. Fourteenth Annual Applied Power Electronics Conference and Exposition. 1999 Conference Proceedings (Cat. No.99CH36285)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.1999.750514","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

Abstract

Two shunt active power filter configurations are analyzed in this paper in order to define new control methods characterized by simple control algorithms and minimum voltage and current transducer requirements. The transfer functions for the two control schemes are determined and analyzed to emphasize the active filter behavior in both steady-state and transient conditions. The performance obtained by the proposed control schemes is similar to that of standard solutions. The experimental results substantially confirm the numerical results obtained by Simulink of Matlab.
具有最小测量要求的有源电力滤波器的控制方法
本文分析了两种并联有源电力滤波器的配置,以确定新的控制方法,其特点是控制算法简单,对电压和电流传感器的要求最小。确定并分析了两种控制方案的传递函数,以强调在稳态和瞬态条件下的有源滤波器行为。所提出的控制方案所获得的性能与标准方案相似。实验结果与Matlab的Simulink得到的数值结果基本吻合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信