{"title":"Investigation of the Dynamics of Liquid Cooling of 3D ICs","authors":"Sakib Islam, Ibrahim M Abdel Motaleb","doi":"10.1109/ISNE.2019.8896425","DOIUrl":null,"url":null,"abstract":"Although 3D IC technology can provide very high integration density, they suffer from having hotspots that may reach 1000’s of degrees. To manage this heat, it is necessary to study the dynamics of cooling and thermal behavior of the ICs. In this study, we report on the dynamics of microchannel liquid cooling using water, R22, and liquid nitrogen. The study shows that using diamond cooling blocks ensures normal operating temperature of 60 ˚C or less, using any of the above coolants. Using SiO2 blocks, only liquid nitrogen can provide acceptable operating temperatures. The study shows also that liquid latent energy and inlet velocity play a major role in the cooling dynamics.","PeriodicalId":405565,"journal":{"name":"2019 8th International Symposium on Next Generation Electronics (ISNE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 8th International Symposium on Next Generation Electronics (ISNE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISNE.2019.8896425","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Although 3D IC technology can provide very high integration density, they suffer from having hotspots that may reach 1000’s of degrees. To manage this heat, it is necessary to study the dynamics of cooling and thermal behavior of the ICs. In this study, we report on the dynamics of microchannel liquid cooling using water, R22, and liquid nitrogen. The study shows that using diamond cooling blocks ensures normal operating temperature of 60 ˚C or less, using any of the above coolants. Using SiO2 blocks, only liquid nitrogen can provide acceptable operating temperatures. The study shows also that liquid latent energy and inlet velocity play a major role in the cooling dynamics.
三维集成电路的液冷动力学研究
虽然3D集成电路技术可以提供非常高的集成密度,但它们的热点可能达到1000度。为了控制这种热量,有必要研究集成电路的冷却动力学和热行为。在这项研究中,我们报告了使用水、R22和液氮的微通道液体冷却的动力学。研究表明,使用金刚石冷却块,使用上述任何一种冷却剂,都可以确保正常工作温度在60˚C或更低。使用SiO2块,只有液氮可以提供可接受的工作温度。研究还表明,液体潜能和进口速度在冷却动力学中起主要作用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信