Supervised Autonomous Electrosurgery for Soft Tissue Resection

J. Ge, H. Saeidi, M. Kam, J. Opfermann, A. Krieger
{"title":"Supervised Autonomous Electrosurgery for Soft Tissue Resection","authors":"J. Ge, H. Saeidi, M. Kam, J. Opfermann, A. Krieger","doi":"10.1109/BIBE52308.2021.9635563","DOIUrl":null,"url":null,"abstract":"Surgical resection is the current clinical standard of care for treating squamous cell carcinoma. Maintaining an adequate tumor resection margin is the key to a good surgical outcome, but tumor edge delineation errors are inevitable with manual surgery due to difficulty in visualization and hand-eye coordination. Surgical automation is a growing field of robotics to relieve surgeon burdens and to achieve a consistent and potentially better surgical outcome. This paper reports a novel robotic supervised autonomous electrosurgery technique for soft tissue resection achieving millimeter accuracy. The tumor resection procedure is decomposed to the subtask level for a more direct understanding and automation. A 4-DOF suction system is developed, and integrated with a 6-DOF electrocautery robot to perform resection experiments. A novel near-infrared fluorescent marker is manually dispensed on cadaver samples to define a pseudotumor, and intraoperatively tracked using a dual-camera system. The autonomous dual-robot resection cooperation workflow is proposed and evaluated in this study. The integrated system achieves autonomous localization of the pseudotumor by tracking the near-infrared marker, and performs supervised autonomous resection in cadaver porcine tongues (N =3). The three pseudotumors were successfully removed from porcine samples. The evaluated average surface and depth resection errors are 1.19 and 1.83mm, respectively. This work is an essential step towards autonomous tumor resections.","PeriodicalId":343724,"journal":{"name":"2021 IEEE 21st International Conference on Bioinformatics and Bioengineering (BIBE)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 21st International Conference on Bioinformatics and Bioengineering (BIBE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIBE52308.2021.9635563","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Surgical resection is the current clinical standard of care for treating squamous cell carcinoma. Maintaining an adequate tumor resection margin is the key to a good surgical outcome, but tumor edge delineation errors are inevitable with manual surgery due to difficulty in visualization and hand-eye coordination. Surgical automation is a growing field of robotics to relieve surgeon burdens and to achieve a consistent and potentially better surgical outcome. This paper reports a novel robotic supervised autonomous electrosurgery technique for soft tissue resection achieving millimeter accuracy. The tumor resection procedure is decomposed to the subtask level for a more direct understanding and automation. A 4-DOF suction system is developed, and integrated with a 6-DOF electrocautery robot to perform resection experiments. A novel near-infrared fluorescent marker is manually dispensed on cadaver samples to define a pseudotumor, and intraoperatively tracked using a dual-camera system. The autonomous dual-robot resection cooperation workflow is proposed and evaluated in this study. The integrated system achieves autonomous localization of the pseudotumor by tracking the near-infrared marker, and performs supervised autonomous resection in cadaver porcine tongues (N =3). The three pseudotumors were successfully removed from porcine samples. The evaluated average surface and depth resection errors are 1.19 and 1.83mm, respectively. This work is an essential step towards autonomous tumor resections.
有监督的自主电外科软组织切除术
手术切除是目前治疗鳞状细胞癌的临床护理标准。保持足够的肿瘤切除边缘是获得良好手术效果的关键,但由于可视化和手眼协调困难,手工手术不可避免地会出现肿瘤边缘描绘错误。手术自动化是机器人技术的一个不断发展的领域,它可以减轻外科医生的负担,实现一致的、潜在的更好的手术结果。本文报道了一种新的机器人监督自主电手术技术,用于软组织切除,达到毫米精度。为了更直接的理解和自动化,将肿瘤切除过程分解为子任务级。开发了一种四自由度吸吸系统,并与六自由度电灼机器人集成进行了电切实验。一种新型的近红外荧光标记物被人工分配到尸体样本上以定义假肿瘤,并在术中使用双摄像头系统进行跟踪。提出并评估了自主双机器人切除合作工作流程。该集成系统通过跟踪近红外标记实现假肿瘤的自主定位,并在猪尸体舌头上进行监督自主切除(N =3)。三个假肿瘤成功地从猪样本中去除。评估的平均表面和深度切除误差分别为1.19和1.83mm。这项工作是迈向自主肿瘤切除的重要一步。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信