Low Voltage Ride Through Method for Wind Turbines Based on Cooperative Control Strategy of Multiple Reactive Power Sources

Baoyu Zhai, Guanchu Chen, Shakenbieke Alimasibieke, Shuchao Liang, Z. Cao, Bingtuan Gao
{"title":"Low Voltage Ride Through Method for Wind Turbines Based on Cooperative Control Strategy of Multiple Reactive Power Sources","authors":"Baoyu Zhai, Guanchu Chen, Shakenbieke Alimasibieke, Shuchao Liang, Z. Cao, Bingtuan Gao","doi":"10.1109/iSPEC54162.2022.10033017","DOIUrl":null,"url":null,"abstract":"With the consumption of traditional energy, renewable energy has gradually become the main force of energy production. To avoid the wind turbines tripping-off caused by the fault of power grid, the renewable energy transmission system usually needs to be equipped with a variety of reactive power compensation devices. To improve the reliability of LVRT (low voltage ride through) of wind turbines under the failure of the sending-end system, a LVRT method for wind turbines based on the cooperative control strategy of multiple reactive power sources is proposed in this paper. Firstly, this paper analyzes the reactive power output capability of the DFIG (doubly fed induction generator) and PMSG (permanent magnetic synchronous generator); and the reactive power output capability of typical reactive compensation devices i.e., SVG (static var generator) and synchronous condenser, is introduced. Secondly, based on the remaining reactive power compensation capacity and response speed of each reactive power source, the voltage regulation participation index defined as VRPI is introduced. Consequently, the cooperative control strategy of multiple reactive power sources is proposed based on the introduced index. Finally, case study of typical fault of the sending-end system integrated with wind turbines is performed, the simulation results show the effectiveness of the proposed cooperative control strategy of multiple reactive power sources.","PeriodicalId":129707,"journal":{"name":"2022 IEEE Sustainable Power and Energy Conference (iSPEC)","volume":"142 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Sustainable Power and Energy Conference (iSPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/iSPEC54162.2022.10033017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

With the consumption of traditional energy, renewable energy has gradually become the main force of energy production. To avoid the wind turbines tripping-off caused by the fault of power grid, the renewable energy transmission system usually needs to be equipped with a variety of reactive power compensation devices. To improve the reliability of LVRT (low voltage ride through) of wind turbines under the failure of the sending-end system, a LVRT method for wind turbines based on the cooperative control strategy of multiple reactive power sources is proposed in this paper. Firstly, this paper analyzes the reactive power output capability of the DFIG (doubly fed induction generator) and PMSG (permanent magnetic synchronous generator); and the reactive power output capability of typical reactive compensation devices i.e., SVG (static var generator) and synchronous condenser, is introduced. Secondly, based on the remaining reactive power compensation capacity and response speed of each reactive power source, the voltage regulation participation index defined as VRPI is introduced. Consequently, the cooperative control strategy of multiple reactive power sources is proposed based on the introduced index. Finally, case study of typical fault of the sending-end system integrated with wind turbines is performed, the simulation results show the effectiveness of the proposed cooperative control strategy of multiple reactive power sources.
基于多无功源协同控制策略的风电机组低压穿越方法
随着传统能源的消耗,可再生能源逐渐成为能源生产的主力军。为避免因电网故障引起的风力发电机组跳闸,可再生能源输电系统通常需要配备各种无功补偿装置。为提高风电机组在发端系统故障情况下的低电压穿越可靠性,提出了一种基于多无功源协同控制策略的风电机组低电压穿越方法。首先,分析了双馈感应发电机(DFIG)和永磁同步发电机(PMSG)的无功输出能力;介绍了静态无功发电机和同步电容器两种典型无功补偿装置的无功输出能力。其次,基于各无功电源的剩余无功补偿容量和响应速度,引入了电压调节参与指标VRPI。在此基础上,提出了基于引入指标的多无功电源协同控制策略。最后,以风力发电机组发送端系统的典型故障为例,仿真结果表明了所提出的多无功源协同控制策略的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信