An Overview in Protection Coordination Methods for Mitigation DGs Penetration in Distribution System. (Dept. E)

Adell S. Amer, Eid Abdelbaki Gouda, A. Elmitwally
{"title":"An Overview in Protection Coordination Methods for Mitigation DGs Penetration in Distribution System. (Dept. E)","authors":"Adell S. Amer, Eid Abdelbaki Gouda, A. Elmitwally","doi":"10.21608/bfemu.2021.209671","DOIUrl":null,"url":null,"abstract":"Received: (15 October, 2021) Revised: (08 December, 2021) Accepted: (09 December, 2021) *Corresponding Author: Adel Amer, Researcher at Electrical Engineering Department, Faculty of Engineering, Mansoura University, (email: eng_adelamer1990@yahoo.com) Eid Abdelbaki Gouda, associate professor at Electrical Engineering Department, Faculty of Engineering, Mansoura University, (email: eaidgoda@mans.edu.eg) Akram Elmitwally, professor at Electrical Engineering Department, Faculty of Engineering, Mansoura University, (email: kelmitwally@yahoo.co.uk) the desire of the consumers for a cheap and reliable energy source in comparison to the large generators, DGs penetration increased as they have smaller capacities, cheap operating costs, low environmental pollution, high efficiency, voltage profile improvement, and enhance the capacity of the electrical grid [1, 2]. Despite the huge benefits gained from the penetration of DGs, the large penetration leads to conflicts in the protection system of distribution systems as the design of distribution networks is a radial network, and penetration of DGs changes the nature of the network [2]. The protection system in the distribution network contains different types of protection devices such as overcurrent relays, and a combination of fuses, and reclosers. These devices are configured in the distribution network as the overcurrent relay is suited at the distribution system substations, reclosers are installed on main feeders, and fuses An Overview in Protection Coordination Methods for Mitigation DGs Penetration in Distribution System","PeriodicalId":179458,"journal":{"name":"MEJ. Mansoura Engineering Journal","volume":"77 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"MEJ. Mansoura Engineering Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/bfemu.2021.209671","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Received: (15 October, 2021) Revised: (08 December, 2021) Accepted: (09 December, 2021) *Corresponding Author: Adel Amer, Researcher at Electrical Engineering Department, Faculty of Engineering, Mansoura University, (email: eng_adelamer1990@yahoo.com) Eid Abdelbaki Gouda, associate professor at Electrical Engineering Department, Faculty of Engineering, Mansoura University, (email: eaidgoda@mans.edu.eg) Akram Elmitwally, professor at Electrical Engineering Department, Faculty of Engineering, Mansoura University, (email: kelmitwally@yahoo.co.uk) the desire of the consumers for a cheap and reliable energy source in comparison to the large generators, DGs penetration increased as they have smaller capacities, cheap operating costs, low environmental pollution, high efficiency, voltage profile improvement, and enhance the capacity of the electrical grid [1, 2]. Despite the huge benefits gained from the penetration of DGs, the large penetration leads to conflicts in the protection system of distribution systems as the design of distribution networks is a radial network, and penetration of DGs changes the nature of the network [2]. The protection system in the distribution network contains different types of protection devices such as overcurrent relays, and a combination of fuses, and reclosers. These devices are configured in the distribution network as the overcurrent relay is suited at the distribution system substations, reclosers are installed on main feeders, and fuses An Overview in Protection Coordination Methods for Mitigation DGs Penetration in Distribution System
配电系统防dg渗透保护协调方法综述。(部门。E)
收稿:(2021年10月15日)修稿:(2021年12月08日)收稿:(2021年12月09日)*通讯作者:Adel Amer,曼苏拉大学工程学院电气工程系研究员(email: eng_adelamer1990@yahoo.com) Eid Abdelbaki Gouda,曼苏拉大学工程学院电气工程系副教授(email:eaidgoda@mans.edu.eg)曼苏拉大学工程学院电气工程系教授Akram Elmitwally(电子邮件:kelmitwally@yahoo.co.uk)与大型发电机相比,消费者对廉价可靠能源的渴望,dg渗透率增加,因为它们容量更小,运行成本便宜,环境污染低,效率高,电压分布改善,并增强电网容量[1,2]。dg的渗透虽然带来了巨大的效益,但由于配电网络的设计是径向网络,dg的渗透改变了网络的性质,因此大的渗透会导致配电系统保护系统的冲突[2]。配电网中的保护系统包含不同类型的保护装置,如过流继电器、熔断器和重合闸的组合。过流继电器适用于配电系统变电站,重合闸安装在主馈线上,熔断器安装在配电网中。缓解配电系统中dg渗透的保护协调方法概述
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信