R. Magadum, Nikhil R. Chitragar, S. Dodamani, P. Gopikrishna
{"title":"Impact on Voltage Stability With Integration of Multiple STATCOM at Different Loading Conditions","authors":"R. Magadum, Nikhil R. Chitragar, S. Dodamani, P. Gopikrishna","doi":"10.1109/ICDCS48716.2020.243608","DOIUrl":null,"url":null,"abstract":"Due to modernization, increase in the population and improvement in the life styles are accelerating the power demand in the recent years. The interconnection of networks, harvesting more power from grid integrated renewable causing drastic change in the power demand curves. This leads to poor voltage profile with more losses in the network. Many researchers are working across the globe to tackle these issues by introducing new equipments, algorithms and techniques. In this paper optimal placement of STATCOM is carried out at different loading condition under disturbance. The proposed methodology is carried out on IEEE-33 nodes network at load factor 1, 1.5 and 2 with disturbance in the network to check the effectiveness of the STATCOM. The obtained result shows new directions for enhancement of the systems parameters.","PeriodicalId":307218,"journal":{"name":"2020 5th International Conference on Devices, Circuits and Systems (ICDCS)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 5th International Conference on Devices, Circuits and Systems (ICDCS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDCS48716.2020.243608","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
Due to modernization, increase in the population and improvement in the life styles are accelerating the power demand in the recent years. The interconnection of networks, harvesting more power from grid integrated renewable causing drastic change in the power demand curves. This leads to poor voltage profile with more losses in the network. Many researchers are working across the globe to tackle these issues by introducing new equipments, algorithms and techniques. In this paper optimal placement of STATCOM is carried out at different loading condition under disturbance. The proposed methodology is carried out on IEEE-33 nodes network at load factor 1, 1.5 and 2 with disturbance in the network to check the effectiveness of the STATCOM. The obtained result shows new directions for enhancement of the systems parameters.