{"title":"Impact on Voltage Stability With Integration of Multiple STATCOM at Different Loading Conditions","authors":"R. Magadum, Nikhil R. Chitragar, S. Dodamani, P. Gopikrishna","doi":"10.1109/ICDCS48716.2020.243608","DOIUrl":null,"url":null,"abstract":"Due to modernization, increase in the population and improvement in the life styles are accelerating the power demand in the recent years. The interconnection of networks, harvesting more power from grid integrated renewable causing drastic change in the power demand curves. This leads to poor voltage profile with more losses in the network. Many researchers are working across the globe to tackle these issues by introducing new equipments, algorithms and techniques. In this paper optimal placement of STATCOM is carried out at different loading condition under disturbance. The proposed methodology is carried out on IEEE-33 nodes network at load factor 1, 1.5 and 2 with disturbance in the network to check the effectiveness of the STATCOM. The obtained result shows new directions for enhancement of the systems parameters.","PeriodicalId":307218,"journal":{"name":"2020 5th International Conference on Devices, Circuits and Systems (ICDCS)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 5th International Conference on Devices, Circuits and Systems (ICDCS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDCS48716.2020.243608","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Due to modernization, increase in the population and improvement in the life styles are accelerating the power demand in the recent years. The interconnection of networks, harvesting more power from grid integrated renewable causing drastic change in the power demand curves. This leads to poor voltage profile with more losses in the network. Many researchers are working across the globe to tackle these issues by introducing new equipments, algorithms and techniques. In this paper optimal placement of STATCOM is carried out at different loading condition under disturbance. The proposed methodology is carried out on IEEE-33 nodes network at load factor 1, 1.5 and 2 with disturbance in the network to check the effectiveness of the STATCOM. The obtained result shows new directions for enhancement of the systems parameters.
不同负载条件下多个STATCOM集成对电压稳定性的影响
近年来,由于现代化、人口的增加和生活方式的改善,加速了对电力的需求。网络的互联,从电网中获取更多的电力,整合了可再生能源,导致电力需求曲线发生了巨大变化。这将导致较差的电压分布和更多的网络损耗。许多研究人员正在全球范围内通过引入新设备、算法和技术来解决这些问题。本文在扰动作用下,对STATCOM在不同载荷条件下的优化布置进行了研究。在负载因子为1、1.5和2的IEEE-33节点网络中进行了干扰测试,验证了该方法的有效性。研究结果为提高系统参数提供了新的方向。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信