Facile and Low-Cost Sensor System for Exploration of Non-Invasive Glucose Measurement

U. Hassan, Muhammad Hamza Zulfiqar, M. Sajid, M. Rehman, K. Riaz
{"title":"Facile and Low-Cost Sensor System for Exploration of Non-Invasive Glucose Measurement","authors":"U. Hassan, Muhammad Hamza Zulfiqar, M. Sajid, M. Rehman, K. Riaz","doi":"10.1109/UCET51115.2020.9205321","DOIUrl":null,"url":null,"abstract":"Among all other disease, diabetes is also one of the major health problems causing nearly 4.5 million deaths per year. According to the international diabetes federation 463 million people were suffering from the diabetes in 2019. It is estimated that this number will raise to 700 million by the year 2045. As, there is no cure for this disease even though level of glucose in the blood should be monitor inflexibly to get rid of more complications. So, monitoring of glucose level in the blood become inexorable need leading the researchers to manufacture a human friendly device which can accurately measure the blood glucose level. Conventionally invasive method is used worldwide to measure the blood glucose level from the blood sample. In this research work facile, low cost glucose characterization sensor is reported for the exploration of non-invasive glucose monitoring using biofluids. In this research work characterization of glucose concentrations from (1mM – 5mM) is performed successfully using facile, low cost glucose sensor. Platinum coated material is used for the sensor electrodes to minimize the cost of the sensor. Platinum based chronoamperometric glucose (PCAG) sensor is proposed in this research work. FR-4 substrate is used for the PCAG sensor. Low cost Portable potentiostat is fabricated to maintain potential across PCAG sensor electrodes. Characterization is performed for aqueous glucose solutions along with the glucose solutions in presence of impurities.","PeriodicalId":163493,"journal":{"name":"2020 International Conference on UK-China Emerging Technologies (UCET)","volume":"96 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Conference on UK-China Emerging Technologies (UCET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UCET51115.2020.9205321","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Among all other disease, diabetes is also one of the major health problems causing nearly 4.5 million deaths per year. According to the international diabetes federation 463 million people were suffering from the diabetes in 2019. It is estimated that this number will raise to 700 million by the year 2045. As, there is no cure for this disease even though level of glucose in the blood should be monitor inflexibly to get rid of more complications. So, monitoring of glucose level in the blood become inexorable need leading the researchers to manufacture a human friendly device which can accurately measure the blood glucose level. Conventionally invasive method is used worldwide to measure the blood glucose level from the blood sample. In this research work facile, low cost glucose characterization sensor is reported for the exploration of non-invasive glucose monitoring using biofluids. In this research work characterization of glucose concentrations from (1mM – 5mM) is performed successfully using facile, low cost glucose sensor. Platinum coated material is used for the sensor electrodes to minimize the cost of the sensor. Platinum based chronoamperometric glucose (PCAG) sensor is proposed in this research work. FR-4 substrate is used for the PCAG sensor. Low cost Portable potentiostat is fabricated to maintain potential across PCAG sensor electrodes. Characterization is performed for aqueous glucose solutions along with the glucose solutions in presence of impurities.
探索无创血糖测量的简易低成本传感器系统
在所有其他疾病中,糖尿病也是每年造成近450万人死亡的主要健康问题之一。根据国际糖尿病联合会的数据,2019年有4.63亿人患有糖尿病。据估计,到2045年,这一数字将增加到7亿。因此,目前还没有治愈这种疾病的方法,即使血液中的葡萄糖水平应该被严格监控,以避免更多的并发症。因此,监测血液中的血糖水平成为一种必然的需要,引导研究人员制造一种能够准确测量血糖水平的人体友好设备。传统的侵入性方法在世界范围内用于从血液样本中测量血糖水平。在这项研究工作中,低成本的葡萄糖表征传感器被报道用于探索利用生物液体进行无创血糖监测。在这项研究工作中,我们成功地使用简单、低成本的葡萄糖传感器对(1mM - 5mM)范围内的葡萄糖浓度进行了表征。传感器电极采用铂涂层材料,使传感器的成本降到最低。本研究提出了铂基计时电流葡萄糖(PCAG)传感器。FR-4衬底用于PCAG传感器。低成本便携式恒电位器是制造来维持电位横跨PCAG传感器电极。对葡萄糖水溶液以及存在杂质的葡萄糖溶液进行表征。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信