{"title":"Flow-through Respirometry: The Basics","authors":"J. Lighton","doi":"10.1093/OSO/9780198830399.003.0008","DOIUrl":null,"url":null,"abstract":"This chapter describes the basic theory behind the most widely used method for measuring metabolic rates: flow-through or open-system respirometry. The advantages and disadvantages of the technique are summarized and the two major types of flow-through respirometry systems are described. Recommendations are given on choosing an appropriate flow rate to compromise between speed of response and signal amplitude; on the nature and importance of the cage time-constant; on using mathematical techniques for response correction by compensating for first-order wash-out kinetics and avoiding mixing errors; the essential differences between oxygen and carbon dioxide analysis; choosing a data acquisition system; generating and measuring flow rates; removing or mathematically compensating for water vapor; important tools; and checklists for deciding on system configuration for a given investigation.","PeriodicalId":405909,"journal":{"name":"Measuring Metabolic Rates","volume":"2013 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measuring Metabolic Rates","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/OSO/9780198830399.003.0008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This chapter describes the basic theory behind the most widely used method for measuring metabolic rates: flow-through or open-system respirometry. The advantages and disadvantages of the technique are summarized and the two major types of flow-through respirometry systems are described. Recommendations are given on choosing an appropriate flow rate to compromise between speed of response and signal amplitude; on the nature and importance of the cage time-constant; on using mathematical techniques for response correction by compensating for first-order wash-out kinetics and avoiding mixing errors; the essential differences between oxygen and carbon dioxide analysis; choosing a data acquisition system; generating and measuring flow rates; removing or mathematically compensating for water vapor; important tools; and checklists for deciding on system configuration for a given investigation.