Small-signal stability monitoring using PMU

P. Chusovitin, A. Pazderin
{"title":"Small-signal stability monitoring using PMU","authors":"P. Chusovitin, A. Pazderin","doi":"10.1109/ENERGYCON.2014.6850439","DOIUrl":null,"url":null,"abstract":"The paper presents results of the research devoted to PMU-based power system small-signal stability monitoring. Proposed method allows tracking in-phase groups of generators and critical generators in the groups by analyzing low-frequency oscillations. Further developed, method is able to identify proximity to power system stability boundary. The technique developed is based on power system equivalent model identification. Identification procedure exploits PMU data. In the paper, applicability of the technique is demonstrated using 9-node power system model.","PeriodicalId":410611,"journal":{"name":"2014 IEEE International Energy Conference (ENERGYCON)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-05-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE International Energy Conference (ENERGYCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ENERGYCON.2014.6850439","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The paper presents results of the research devoted to PMU-based power system small-signal stability monitoring. Proposed method allows tracking in-phase groups of generators and critical generators in the groups by analyzing low-frequency oscillations. Further developed, method is able to identify proximity to power system stability boundary. The technique developed is based on power system equivalent model identification. Identification procedure exploits PMU data. In the paper, applicability of the technique is demonstrated using 9-node power system model.
采用PMU进行小信号稳定性监测
本文介绍了基于单片机的电力系统小信号稳定监测的研究成果。该方法通过分析低频振荡,实现对同相发电机组和关键发电机组的跟踪。进一步发展,该方法能够识别接近电力系统稳定边界。该技术是基于电力系统等效模型辨识的。识别程序利用PMU数据。本文以9节点电力系统模型为例,验证了该技术的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信