{"title":"Corona degradation of polyethylene under multiple stress conditions","authors":"K. Wolter, M. Shaw, J. Johnson","doi":"10.1109/ICEI.1980.7470862","DOIUrl":null,"url":null,"abstract":"The major volatile degradation products of polyethylene exposed to partial discharges are hydrogen and carbon dioxide, with lesser amounts of carbon monoxide and methane. The effect of temperature and voltage on the composition and amounts of degradation product gases has been investigated.","PeriodicalId":113059,"journal":{"name":"1980 IEEE International Conference on Electrical Insulation","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1980-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1980 IEEE International Conference on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEI.1980.7470862","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
The major volatile degradation products of polyethylene exposed to partial discharges are hydrogen and carbon dioxide, with lesser amounts of carbon monoxide and methane. The effect of temperature and voltage on the composition and amounts of degradation product gases has been investigated.