A methodology to determine Transient Recovery Voltage in short-line fault

D. Dorantes, M. H. Ángeles
{"title":"A methodology to determine Transient Recovery Voltage in short-line fault","authors":"D. Dorantes, M. H. Ángeles","doi":"10.1109/ROPEC.2016.7830591","DOIUrl":null,"url":null,"abstract":"This paper presents a methodology to determine the appropriate parameters to establish the capability of Transient Recovery Voltage (TRV) of a 145kV circuit breaker. The methodology involves the combination of a simulation procedure in the Electromagnetic Transients Program (ATP) and an analytical technique based on the IEEE C37.06 and IEC 62271-100 standards to evaluate the effect of the source side voltage and line side voltage on the TRV in a short-line fault (SLF). The results obtained on TRV of the circuit breaker capability by simulation and analytical calculatión, acording to the IEEE and IEC standards, are compared using the Matlab program.","PeriodicalId":166098,"journal":{"name":"2016 IEEE International Autumn Meeting on Power, Electronics and Computing (ROPEC)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Autumn Meeting on Power, Electronics and Computing (ROPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ROPEC.2016.7830591","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents a methodology to determine the appropriate parameters to establish the capability of Transient Recovery Voltage (TRV) of a 145kV circuit breaker. The methodology involves the combination of a simulation procedure in the Electromagnetic Transients Program (ATP) and an analytical technique based on the IEEE C37.06 and IEC 62271-100 standards to evaluate the effect of the source side voltage and line side voltage on the TRV in a short-line fault (SLF). The results obtained on TRV of the circuit breaker capability by simulation and analytical calculatión, acording to the IEEE and IEC standards, are compared using the Matlab program.
短路故障暂态恢复电压的确定方法
本文提出了一种确定145kV断路器暂态恢复电压(TRV)能力的适当参数的方法。该方法将电磁瞬变程序(ATP)中的仿真程序与基于IEEE C37.06和IEC 62271-100标准的分析技术相结合,以评估短线故障(SLF)中源侧电压和线侧电压对TRV的影响。根据IEEE和IEC标准,通过仿真和分析calculatión得到了断路器性能的TRV值,并利用Matlab程序进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信