{"title":"Development of Micro-channel Arrays for Peripheral Nerve Recording","authors":"D. Edell, R. Riso, H. Herr","doi":"10.5220/0005091500050012","DOIUrl":null,"url":null,"abstract":"MicroTube Array (MTA) technology was developed to create an axon regeneration interface for exchanging motor and sensory data with residual nerves. Future clinical application will include sensory-motor transducers for individuals with limb amputation. In this pilot study, a small matrix (9) of MTAs 1, 3 and 5mm long with either 99um, 200um or 287um diameter MicroTubes (MTs) filling nerve cuffs of 3mm in diameter were implanted in tibial nerve of NZW rabbits and histologically evaluated after more than 6 months post-op. Full regeneration was observed in all 3 lengths for 287um MTAs, and for all three diameters of MTs with 1mm length. The remaining implants were mechanically dislodged during the healing phase. A second implant set was designed to include 12 platinum-iridium wire electrodes direct wired to a percutaneous connector. Successful recordings of useful amplitudes were observed during reflex righting behaviour for over 2 years before the anticipated wire breakage ended the experiments.","PeriodicalId":167011,"journal":{"name":"International Congress on Neurotechnology, Electronics and Informatics","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Congress on Neurotechnology, Electronics and Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5220/0005091500050012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

MicroTube Array (MTA) technology was developed to create an axon regeneration interface for exchanging motor and sensory data with residual nerves. Future clinical application will include sensory-motor transducers for individuals with limb amputation. In this pilot study, a small matrix (9) of MTAs 1, 3 and 5mm long with either 99um, 200um or 287um diameter MicroTubes (MTs) filling nerve cuffs of 3mm in diameter were implanted in tibial nerve of NZW rabbits and histologically evaluated after more than 6 months post-op. Full regeneration was observed in all 3 lengths for 287um MTAs, and for all three diameters of MTs with 1mm length. The remaining implants were mechanically dislodged during the healing phase. A second implant set was designed to include 12 platinum-iridium wire electrodes direct wired to a percutaneous connector. Successful recordings of useful amplitudes were observed during reflex righting behaviour for over 2 years before the anticipated wire breakage ended the experiments.
外周神经记录微通道阵列的研制
微管阵列(MicroTube Array, MTA)技术用于创建轴突再生接口,用于与残余神经交换运动和感觉数据。未来的临床应用将包括肢体截肢患者的感觉-运动传感器。在这项初步研究中,将一组直径为99um、200um或287um、长度为1,3和5mm的微型微管(MTs)植入NZW兔胫骨神经,并在术后6个多月后进行组织学评估。287um mta的三种长度以及1mm长度的mta的三种直径均可观察到完全再生。剩余的种植体在愈合阶段机械移位。第二套植入物设计包括12个铂铱丝电极直接连接到经皮连接器。在预期的断线结束实验之前,在反射矫正行为中成功记录了有用的振幅超过2年。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信