The Effect of AlTi5B1 Masteralloy on Al-Si Alloy Casts Grain Size

T. Vlach, Roman Horký
{"title":"The Effect of AlTi5B1 Masteralloy on Al-Si Alloy Casts Grain Size","authors":"T. Vlach, Roman Horký","doi":"10.21496/ams.2023.004","DOIUrl":null,"url":null,"abstract":": This article deals with the issue of silumin inoculation. Two alloys, AlSi7Mg0.3 and AlSi10.5Cu1.2Mn0.8Ni1.2, were selected. 4 pieces of castings were cast from each alloy. One casting was not inoculated and 3 castings were inoculated using AlTi5B1 prealloy in concentrations of 0.05 wt. %, 0.1 wt % and 0.2 wt. % Ti. The castings were cast into metal molds preheated to a temperature of 200°C ± 5°C. In total, 8 pieces of metallographic cuttings were prepared for each alloy. Four samples were taken from the bottom part of the casting and four samples from the middle part of the casting. Secondary axes of DAS dendrites were measured using a microscope. Subsequently, the microhardness of the solid solution α was measured according to Vickers.","PeriodicalId":135905,"journal":{"name":"Acta Mechanica Slovaca","volume":"235 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Mechanica Slovaca","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21496/ams.2023.004","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

: This article deals with the issue of silumin inoculation. Two alloys, AlSi7Mg0.3 and AlSi10.5Cu1.2Mn0.8Ni1.2, were selected. 4 pieces of castings were cast from each alloy. One casting was not inoculated and 3 castings were inoculated using AlTi5B1 prealloy in concentrations of 0.05 wt. %, 0.1 wt % and 0.2 wt. % Ti. The castings were cast into metal molds preheated to a temperature of 200°C ± 5°C. In total, 8 pieces of metallographic cuttings were prepared for each alloy. Four samples were taken from the bottom part of the casting and four samples from the middle part of the casting. Secondary axes of DAS dendrites were measured using a microscope. Subsequently, the microhardness of the solid solution α was measured according to Vickers.
AlTi5B1母粒合金对Al-Si合金铸件晶粒尺寸的影响
本文讨论了silumin的接种问题。选用AlSi7Mg0.3和AlSi10.5Cu1.2Mn0.8Ni1.2两种合金。每种合金共铸造4件铸件。用浓度分别为0.05 wt. %、0.1 wt. %和0.2 wt. % Ti的AlTi5B1预合金对3个铸件进行接种。将铸件浇注在预热至200℃±5℃的金属模具中。每种合金共制备了8块金相岩屑。从铸件底部取4个样品,从铸件中部取4个样品。用显微镜测量DAS树突的次轴。随后,采用维氏法测定固溶体α的显微硬度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信