H. Ismailoğlu, O. Kalenderli, M. Ozkaya, I. Gonenc
{"title":"Breakdown in compressed N/sub 2/ under impulse voltages","authors":"H. Ismailoğlu, O. Kalenderli, M. Ozkaya, I. Gonenc","doi":"10.1109/CEIDP.1997.641147","DOIUrl":null,"url":null,"abstract":"Breakdown strength of N/sub 2/ under standard lightning impulse voltages in non-uniform field was experimentally investigated. The experiments were carried out with sphere-plane electrode system with protrusion and without protrusion. The electrode gap spacing and the relative gas pressure were varied within the range of 5 mm to 25 mm and of 0 bar to 4 bars, respectively. At each pressure and gap spacing, impulse breakdown voltages for both negative and positive polarities were measured. The 50% breakdown values were obtained using the least squares. Breakdown voltage of N/sub 2/ increases either with an increasing gap spacing and/or with an increasing gas pressure. Breakdown voltages of N/sub 2/ in used electrode system under positive impulses, were higher than those of under negative impulses at small gap spacing; but much lower at greater gap spacing. In the experiments, breakdown voltages of sphere-plane with protrusion electrode system were found to be higher than those of sphere-plane electrode system under both polarities.","PeriodicalId":176239,"journal":{"name":"IEEE 1997 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE 1997 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1997.641147","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Breakdown strength of N/sub 2/ under standard lightning impulse voltages in non-uniform field was experimentally investigated. The experiments were carried out with sphere-plane electrode system with protrusion and without protrusion. The electrode gap spacing and the relative gas pressure were varied within the range of 5 mm to 25 mm and of 0 bar to 4 bars, respectively. At each pressure and gap spacing, impulse breakdown voltages for both negative and positive polarities were measured. The 50% breakdown values were obtained using the least squares. Breakdown voltage of N/sub 2/ increases either with an increasing gap spacing and/or with an increasing gas pressure. Breakdown voltages of N/sub 2/ in used electrode system under positive impulses, were higher than those of under negative impulses at small gap spacing; but much lower at greater gap spacing. In the experiments, breakdown voltages of sphere-plane with protrusion electrode system were found to be higher than those of sphere-plane electrode system under both polarities.