Autonomous wind turbines with Doubly-Fed Induction Generators

S. Z. Farooqui
{"title":"Autonomous wind turbines with Doubly-Fed Induction Generators","authors":"S. Z. Farooqui","doi":"10.1109/ICEENVIRON.2009.5398667","DOIUrl":null,"url":null,"abstract":"In this paper, a vector control mechanism has been suggested and applied to simulate the operation of a Doubly-Fed Induction Generator (DFIG) attached to an isolated off-the-grid wind turbine, to demonstrate that these generators can be used at lower costs to control the power quality in stand alone wind turbines. In order to achieve this end, the alignment of the d-axis of the synchronously rotating reference frame is imposed along the stator flux vector. A wide range of sub and super synchronous operating speeds are investigated using a 5th order model. Artificially generated wind speeds are used to acquire variable speed operation. Twenty seconds simulations are presented by feeding the stator d and q current components. The input current components have been drawn from the simulation of a rotor short circuited, grid connected DFIG, starting from rest. The synchronous frequency ωs, and stator voltage components Vrefds and Vrefqs are imposed as constant demands in the control equations. Simulations are carried out by independently iteratively solving the differential equations for the magnetizing current and the two rotor current components. Solutions of these equations respectively generate the demands for the d-component of the rotor current, and the two components of the rotor voltage. The demand for the second component of the rotor current is obtained directly from the field alignment condition. The stator current input data also includes a fault induction response to a stator voltage step change. Simulation results faithfully reproduce the initial conditions, indicating the validity of the vector control scheme for stand alone operations of the DFIG.","PeriodicalId":211736,"journal":{"name":"2009 3rd International Conference on Energy and Environment (ICEE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 3rd International Conference on Energy and Environment (ICEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEENVIRON.2009.5398667","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

In this paper, a vector control mechanism has been suggested and applied to simulate the operation of a Doubly-Fed Induction Generator (DFIG) attached to an isolated off-the-grid wind turbine, to demonstrate that these generators can be used at lower costs to control the power quality in stand alone wind turbines. In order to achieve this end, the alignment of the d-axis of the synchronously rotating reference frame is imposed along the stator flux vector. A wide range of sub and super synchronous operating speeds are investigated using a 5th order model. Artificially generated wind speeds are used to acquire variable speed operation. Twenty seconds simulations are presented by feeding the stator d and q current components. The input current components have been drawn from the simulation of a rotor short circuited, grid connected DFIG, starting from rest. The synchronous frequency ωs, and stator voltage components Vrefds and Vrefqs are imposed as constant demands in the control equations. Simulations are carried out by independently iteratively solving the differential equations for the magnetizing current and the two rotor current components. Solutions of these equations respectively generate the demands for the d-component of the rotor current, and the two components of the rotor voltage. The demand for the second component of the rotor current is obtained directly from the field alignment condition. The stator current input data also includes a fault induction response to a stator voltage step change. Simulation results faithfully reproduce the initial conditions, indicating the validity of the vector control scheme for stand alone operations of the DFIG.
带有双馈感应发电机的自主风力涡轮机
本文提出了一种矢量控制机制,并将其应用于孤立离网风力发电机组上的双馈感应发电机(DFIG)的运行模拟,以证明该发电机可以以较低的成本控制独立风力发电机组的电能质量。为了达到这一目的,同步旋转参考系的d轴沿定子磁通矢量施加对准。利用五阶模型研究了大范围的次同步和超同步运行速度。人工产生的风速用于变速操作。通过输入定子d和q电流分量进行了20秒的仿真。通过对转子短路、并网DFIG的仿真,得出了输入电流分量。在控制方程中,同步频率ωs和定子电压分量Vrefds和Vrefqs作为常数要求施加。通过独立迭代求解磁化电流和两个转子电流分量的微分方程进行了仿真。这些方程的解分别产生了对转子电流d分量和转子电压两分量的需求。对转子电流第二分量的需求直接从磁场对准条件中得到。定子电流输入数据还包括对定子电压阶跃变化的故障感应响应。仿真结果忠实地再现了初始条件,表明了矢量控制方案对DFIG单机运行的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信