{"title":"Generalized controller for small wind turbines working grid-connected and stand-alone","authors":"M. Rizo, E. Bueno, A. Dell'Aquila, Marco Liserre, R. Mastromauro","doi":"10.1109/ICCEP.2011.6036328","DOIUrl":null,"url":null,"abstract":"Distributed power generation systems may be required to work in both grid-connected and stand-alone modes for ensuring the supply of critical local loads, maybe organized in micro-grids. Every time the micro-grid is disconnected and reconnected from the grid, a change in the control scheme is required leading to undesired transients and even lost of stability. In this paper, the use of the droop control is extended to both operation modes without commutating the control schemes. An islanding detection method is employed together with a synchronization algorithm achieving a successful micro-grid reconnection procedure. Simulation results prove the effectiveness of the proposed solution.","PeriodicalId":403158,"journal":{"name":"2011 International Conference on Clean Electrical Power (ICCEP)","volume":"32 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Clean Electrical Power (ICCEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCEP.2011.6036328","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Distributed power generation systems may be required to work in both grid-connected and stand-alone modes for ensuring the supply of critical local loads, maybe organized in micro-grids. Every time the micro-grid is disconnected and reconnected from the grid, a change in the control scheme is required leading to undesired transients and even lost of stability. In this paper, the use of the droop control is extended to both operation modes without commutating the control schemes. An islanding detection method is employed together with a synchronization algorithm achieving a successful micro-grid reconnection procedure. Simulation results prove the effectiveness of the proposed solution.
并网单机小型风力发电机组的通用控制器
分布式发电系统可能需要在并网和独立模式下工作,以确保关键的局部负荷的供应,可能组织在微电网中。每次微电网与电网断开或重新连接时,都需要改变控制方案,从而导致不期望的瞬变甚至失去稳定性。本文在不改变控制方案的情况下,将下垂控制扩展到两种工作模式。采用孤岛检测方法和同步算法,实现了微电网的成功重联。仿真结果证明了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信