Operation of Distribution Network with Distributed Generation in Floating Mode

Sangeeta Das, D. Das, A. Patra
{"title":"Operation of Distribution Network with Distributed Generation in Floating Mode","authors":"Sangeeta Das, D. Das, A. Patra","doi":"10.1109/ISAP48318.2019.9065942","DOIUrl":null,"url":null,"abstract":"This paper presents a framework for operation of the distribution network with distributed generation in floating mode. The term ‘floating mode’ is aimed at making the distribution network draw negligible power from the grid along with the reduction of power losses and improvement of voltage profile. Under floating mode operation, the distribution network remains connected with the grid to allow the grid to dictate the voltage and frequency. If load demand increases, the grid can supply the additional load power and if the load demand decreases, the excess power from the network will be fed back to the grid. This proposed approach is achieved in detail using dispatchable DGs operating at lagging power factor considering three load levels. Fuzzy max-min principle is used to find the optimal location of DGs. The optimization of the DG sizing is achieved using a combination of fuzzy maxmin technique with genetic algorithm. Effectiveness of the proposed methodology is presented through an example of a 60 node distribution network.","PeriodicalId":316020,"journal":{"name":"2019 20th International Conference on Intelligent System Application to Power Systems (ISAP)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 20th International Conference on Intelligent System Application to Power Systems (ISAP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISAP48318.2019.9065942","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents a framework for operation of the distribution network with distributed generation in floating mode. The term ‘floating mode’ is aimed at making the distribution network draw negligible power from the grid along with the reduction of power losses and improvement of voltage profile. Under floating mode operation, the distribution network remains connected with the grid to allow the grid to dictate the voltage and frequency. If load demand increases, the grid can supply the additional load power and if the load demand decreases, the excess power from the network will be fed back to the grid. This proposed approach is achieved in detail using dispatchable DGs operating at lagging power factor considering three load levels. Fuzzy max-min principle is used to find the optimal location of DGs. The optimization of the DG sizing is achieved using a combination of fuzzy maxmin technique with genetic algorithm. Effectiveness of the proposed methodology is presented through an example of a 60 node distribution network.
浮动模式下分布式发电配电网的运行
提出了一种基于浮动模式的分布式发电配电网运行框架。“浮动模式”一词旨在使配电网从电网中获取可忽略不计的电力,同时减少电力损耗和改善电压分布。在浮动运行模式下,配电网与电网保持连接,允许电网决定电压和频率。当负荷需求增加时,电网可以提供额外的负荷电力;当负荷需求减少时,电网的多余电力将反馈给电网。该方法使用可调度dg在考虑三个负载水平的滞后功率因数下运行,详细实现了该方法。采用模糊最大-最小原则寻找dg的最优位置。将模糊最大值技术与遗传算法相结合,实现了DG尺寸的优化。通过一个60节点配电网络的实例,验证了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信