Effect of device mismatch on the phase and amplitude accuracy in LC quadrature VCOs

I.R. Chamas, S. Raman
{"title":"Effect of device mismatch on the phase and amplitude accuracy in LC quadrature VCOs","authors":"I.R. Chamas, S. Raman","doi":"10.1109/RWS.2006.1615189","DOIUrl":null,"url":null,"abstract":"An overview of cross-coupled LC tank quadrature VCOs is presented. Then, the effect of mismatch on the amplitude and quadrature phase accuracy is discussed. In particular, we focus on the mismatch between the negative resistance (Rneg) and quadrature resistance (R quad) of the two VCOs. By considering a first order linear model of the QVCO, it is shown that a mismatch in Rneg generates an imbalance in the quadrature phase but preserves the amplitude accuracy, whereas a mismatch in Rquad leads to both a relative amplitude error and phase imbalance. Furthermore, the mismatch leads to an effective coupling transconductance GMceff that in turn causes a deviation in the steady state oscillation frequency. The developed analysis is verified using SpectreRF simulation of a parallel QVCO topology (PQVCO)","PeriodicalId":244560,"journal":{"name":"2006 IEEE Radio and Wireless Symposium","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 IEEE Radio and Wireless Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RWS.2006.1615189","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

An overview of cross-coupled LC tank quadrature VCOs is presented. Then, the effect of mismatch on the amplitude and quadrature phase accuracy is discussed. In particular, we focus on the mismatch between the negative resistance (Rneg) and quadrature resistance (R quad) of the two VCOs. By considering a first order linear model of the QVCO, it is shown that a mismatch in Rneg generates an imbalance in the quadrature phase but preserves the amplitude accuracy, whereas a mismatch in Rquad leads to both a relative amplitude error and phase imbalance. Furthermore, the mismatch leads to an effective coupling transconductance GMceff that in turn causes a deviation in the steady state oscillation frequency. The developed analysis is verified using SpectreRF simulation of a parallel QVCO topology (PQVCO)
器件失配对LC正交压控振荡器相位和幅度精度的影响
概述了交叉耦合LC罐正交vco。然后,讨论了失配对幅值精度和交相精度的影响。我们特别关注了两个vco的负电阻(rnegg)和正交电阻(R四次方)之间的不匹配。通过考虑QVCO的一阶线性模型,结果表明,Rneg的失配会产生正交相位的不平衡,但保持了幅度精度,而Rquad的失配会导致相对幅度误差和相位不平衡。此外,失配会导致有效的耦合跨导GMceff,从而导致稳态振荡频率的偏差。利用SpectreRF模拟并联QVCO拓扑(PQVCO)验证了所开发的分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信