Phase-to-Phase Switching Surges on Line Energization

I. B. Johnson, R. F. Silva, D. Wilson
{"title":"Phase-to-Phase Switching Surges on Line Energization","authors":"I. B. Johnson, R. F. Silva, D. Wilson","doi":"10.1109/AIEEPAS.1962.4501319","DOIUrl":null,"url":null,"abstract":"Data from an investigation of a miniature system are given on the magnitude and wave shape of phase-to-phase switching surges produced upon energization of a transformer-terminated line. The effects of line length, terminating impedances, and switching conditions are included. This information is needed for the evaluation of phase-to-phase clearances and insulation, since there appears to be little, if any, information published on the matter.","PeriodicalId":118797,"journal":{"name":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1962-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AIEEPAS.1962.4501319","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

Data from an investigation of a miniature system are given on the magnitude and wave shape of phase-to-phase switching surges produced upon energization of a transformer-terminated line. The effects of line length, terminating impedances, and switching conditions are included. This information is needed for the evaluation of phase-to-phase clearances and insulation, since there appears to be little, if any, information published on the matter.
线路通电时的相对相开关浪涌
通过对一个微型系统的研究,给出了在变压器端接线路通电时产生的相对相开关浪涌的大小和波形。考虑了线路长度、终端阻抗和开关条件的影响。评价相对相的间隙和绝缘需要这些资料,因为在这方面发表的资料很少,如果有的话。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信