{"title":"Analysis of Substation 35kV Reactance Switch Fault Based on ATP-EMTP","authors":"Yanfei Zhuang, Haiyan Yuan","doi":"10.1109/CICED50259.2021.9556729","DOIUrl":null,"url":null,"abstract":"This paper Initial on the solar parabolic trough collectors…Operating overvoltage is a common overvoltage in the power system, and it is closely related to the operation mode of the power grid and equipment characteristics etc. Normal equipment in the system has a large insulation margin. Operating overvoltage can not cause damage to it, but it can pose a greater threat to equipment with weak insulation, which will affect the safe operation of the power grid. In the paper, a simulation was produced based on the electromagnetic transient simulation software ATP-EMTP for the 35kV reactance fault in a substation. The overvoltages subjected to the reactance and its switching equipment are analyzed , and the causes of the equipment damage were analyzed in detail. A reference treatment plan is proposed to provide guidance for practice.","PeriodicalId":221387,"journal":{"name":"2021 China International Conference on Electricity Distribution (CICED)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 China International Conference on Electricity Distribution (CICED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CICED50259.2021.9556729","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper Initial on the solar parabolic trough collectors…Operating overvoltage is a common overvoltage in the power system, and it is closely related to the operation mode of the power grid and equipment characteristics etc. Normal equipment in the system has a large insulation margin. Operating overvoltage can not cause damage to it, but it can pose a greater threat to equipment with weak insulation, which will affect the safe operation of the power grid. In the paper, a simulation was produced based on the electromagnetic transient simulation software ATP-EMTP for the 35kV reactance fault in a substation. The overvoltages subjected to the reactance and its switching equipment are analyzed , and the causes of the equipment damage were analyzed in detail. A reference treatment plan is proposed to provide guidance for practice.