Analysis of Substation 35kV Reactance Switch Fault Based on ATP-EMTP

Yanfei Zhuang, Haiyan Yuan
{"title":"Analysis of Substation 35kV Reactance Switch Fault Based on ATP-EMTP","authors":"Yanfei Zhuang, Haiyan Yuan","doi":"10.1109/CICED50259.2021.9556729","DOIUrl":null,"url":null,"abstract":"This paper Initial on the solar parabolic trough collectors…Operating overvoltage is a common overvoltage in the power system, and it is closely related to the operation mode of the power grid and equipment characteristics etc. Normal equipment in the system has a large insulation margin. Operating overvoltage can not cause damage to it, but it can pose a greater threat to equipment with weak insulation, which will affect the safe operation of the power grid. In the paper, a simulation was produced based on the electromagnetic transient simulation software ATP-EMTP for the 35kV reactance fault in a substation. The overvoltages subjected to the reactance and its switching equipment are analyzed , and the causes of the equipment damage were analyzed in detail. A reference treatment plan is proposed to provide guidance for practice.","PeriodicalId":221387,"journal":{"name":"2021 China International Conference on Electricity Distribution (CICED)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 China International Conference on Electricity Distribution (CICED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CICED50259.2021.9556729","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper Initial on the solar parabolic trough collectors…Operating overvoltage is a common overvoltage in the power system, and it is closely related to the operation mode of the power grid and equipment characteristics etc. Normal equipment in the system has a large insulation margin. Operating overvoltage can not cause damage to it, but it can pose a greater threat to equipment with weak insulation, which will affect the safe operation of the power grid. In the paper, a simulation was produced based on the electromagnetic transient simulation software ATP-EMTP for the 35kV reactance fault in a substation. The overvoltages subjected to the reactance and its switching equipment are analyzed , and the causes of the equipment damage were analyzed in detail. A reference treatment plan is proposed to provide guidance for practice.
基于ATP-EMTP的变电站35kV电抗开关故障分析
运行过电压是电力系统中常见的过电压,它与电网的运行方式、设备特性等密切相关。系统中正常设备的绝缘余量较大。运行过电压不会对其造成损坏,但会对绝缘薄弱的设备造成较大的威胁,影响电网的安全运行。本文基于电磁暂态仿真软件ATP-EMTP对某变电站35kV电抗故障进行了仿真。分析了电抗及其开关设备所受的过电压,详细分析了设备损坏的原因。提出了一种参考治疗方案,为实践提供指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信