Centralized voltage control method using plural D-STATCOM with controllable dead band in distribution system with renewable energy

Naoyuki Takahashi, Y. Hayashi
{"title":"Centralized voltage control method using plural D-STATCOM with controllable dead band in distribution system with renewable energy","authors":"Naoyuki Takahashi, Y. Hayashi","doi":"10.1109/ISGTEurope.2012.6465827","DOIUrl":null,"url":null,"abstract":"The authors propose voltage control method using centralized control of D-STATCOM with controllable dead band to control all the node voltages dynamically. To maximize the acceptable amount of RES, centralized control system meters each node voltage installed D-STATCOM, and control all the node voltages based on each node voltage. The target voltage of D-STATCOM near a substation is modified by another node voltage to regulate all the node voltages within proper range. The amount of correction for the target voltage is determined by the amount of deviation from a threshold which is set between upper limits of the dead band and proper range. Conventional method has potential to command inappropriate reactive power due to delay time based on communication time and calculation for commands of reactive power. Proposed method compensates for the lack of reactive power based on the delay time using the predictive control.","PeriodicalId":244881,"journal":{"name":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGTEurope.2012.6465827","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

The authors propose voltage control method using centralized control of D-STATCOM with controllable dead band to control all the node voltages dynamically. To maximize the acceptable amount of RES, centralized control system meters each node voltage installed D-STATCOM, and control all the node voltages based on each node voltage. The target voltage of D-STATCOM near a substation is modified by another node voltage to regulate all the node voltages within proper range. The amount of correction for the target voltage is determined by the amount of deviation from a threshold which is set between upper limits of the dead band and proper range. Conventional method has potential to command inappropriate reactive power due to delay time based on communication time and calculation for commands of reactive power. Proposed method compensates for the lack of reactive power based on the delay time using the predictive control.
可再生能源配电系统中采用可控制死区复数D-STATCOM集中电压控制方法
提出了采用可控制死区D-STATCOM集中控制的电压控制方法,对各节点电压进行动态控制。为了使可接受的RES值最大化,集中控制系统对安装D-STATCOM的各个节点电压进行测量,并根据每个节点电压对所有节点电压进行控制。变电站附近的D-STATCOM的目标电压通过另一个节点电压进行修改,使所有节点电压调节在适当范围内。目标电压的校正量由从死区上限和适当范围之间设置的阈值的偏差量决定。基于通信时间和无功指令计算的传统方法有可能由于时延而导致无功指令不正确。提出了一种基于延迟时间的预测控制补偿无功功率不足的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信