State evaluation model of distribution transformer considering environmental factors and operation data

Chen Yingyu, Zhang Yubo, Wang Youyuan, Fang Jian
{"title":"State evaluation model of distribution transformer considering environmental factors and operation data","authors":"Chen Yingyu, Zhang Yubo, Wang Youyuan, Fang Jian","doi":"10.1109/eic47619.2020.9158769","DOIUrl":null,"url":null,"abstract":"In the fault diagnosis of distribution transformer, in order to fully consider the influence of environmental factors and operation data on distribution transformer, a method of fault diagnosis model of distribution transformer considering environmental factors and operation data is established. First of all, according to the fault data of distribution transformer provided by Guangzhou Power Supply Bureau in recent five years, the environmental factors causing the fault of distribution transformer are calculated. The association rule mining algorithm is used to mine the external environmental factors of distribution transformer fault, and find out the external environmental factors that have a high impact on distribution transformer; secondly, according to the operation data of distribution transformer fault, select the important operation data of distribution transformer fault, and calculate the deviation between the data and the standard value, and take the final result as one of the evaluation indicators; then, in the use of Based on the evaluation of internal test data, the external factors and operation data are fully integrated into the model to establish a complete evaluation model. Finally, the health level of a 10kV distribution transformer in Guangzhou is evaluated in real time in one day. The research of this paper can provide reference for the fault diagnosis and operation maintenance of 10kV distribution transformer","PeriodicalId":286019,"journal":{"name":"2020 IEEE Electrical Insulation Conference (EIC)","volume":"24 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/eic47619.2020.9158769","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In the fault diagnosis of distribution transformer, in order to fully consider the influence of environmental factors and operation data on distribution transformer, a method of fault diagnosis model of distribution transformer considering environmental factors and operation data is established. First of all, according to the fault data of distribution transformer provided by Guangzhou Power Supply Bureau in recent five years, the environmental factors causing the fault of distribution transformer are calculated. The association rule mining algorithm is used to mine the external environmental factors of distribution transformer fault, and find out the external environmental factors that have a high impact on distribution transformer; secondly, according to the operation data of distribution transformer fault, select the important operation data of distribution transformer fault, and calculate the deviation between the data and the standard value, and take the final result as one of the evaluation indicators; then, in the use of Based on the evaluation of internal test data, the external factors and operation data are fully integrated into the model to establish a complete evaluation model. Finally, the health level of a 10kV distribution transformer in Guangzhou is evaluated in real time in one day. The research of this paper can provide reference for the fault diagnosis and operation maintenance of 10kV distribution transformer
考虑环境因素和运行数据的配电变压器状态评价模型
在配电变压器故障诊断中,为了充分考虑环境因素和运行数据对配电变压器的影响,建立了一种考虑环境因素和运行数据的配电变压器故障诊断模型方法。首先,根据广州市供电局近五年提供的配电变压器故障数据,对引起配电变压器故障的环境因素进行了计算。利用关联规则挖掘算法挖掘配电变压器故障的外部环境因素,找出对配电变压器影响较大的外部环境因素;其次,根据配电变压器故障运行数据,选取配电变压器故障的重要运行数据,计算数据与标准值的偏差,并将最终结果作为评价指标之一;然后,在利用内部试验数据评价的基础上,将外部因素和运行数据充分整合到模型中,建立完整的评价模型。最后,对广州某10kV配电变压器进行了一天内的健康水平实时评价。本文的研究可为10kV配电变压器的故障诊断和运行维护提供参考
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信