A Novel Archimedes Spiral Antenna Used for PD Measurement at Repetitive Square Wave Voltages

Yuanquan Gong, Peng Wang, Wanya Zhou, Jiawei Zhang, A. Cavallini
{"title":"A Novel Archimedes Spiral Antenna Used for PD Measurement at Repetitive Square Wave Voltages","authors":"Yuanquan Gong, Peng Wang, Wanya Zhou, Jiawei Zhang, A. Cavallini","doi":"10.1109/CEIDP.2018.8544893","DOIUrl":null,"url":null,"abstract":"Partial discharge(PD) measurements under repetitive impulsive voltages should be performed on insulation systems of rotating machines fed by voltage converters for type and qualification tests according to International Electrotechnical Commission (IEC) standard. Compared with well-established PD test technologies at sinusoidal voltages, more issues should be considered when PD detection are carried out using repetitive impulsive voltages, because PD pulses coming from the samples and the disturbance coming from impulsive voltage generator often have similar features in both time and frequency domains. Among all PD measurement methods, ultra-high frequency (UHF) technologies are recommended to be used under repetitive impulsive voltage conditions because the UHF sensors with appropriate bandwidth can receive PD energy in high frequency range with high signal to noise ratio (SNR). However, when performing PD tests using UHF method at impulsive voltages, the test sensitivity depends largely on the performance of the antenna in frequency domain. This paper, therefore, aims to present a design of a novel Archimedes Spiral Antenna (ASA) specially used for PD tests at impulsive voltages. Through the electromagnetic simulation, the optimized parameters of the antenna are selected and discussed. The PD tests at repetitive impulsive voltages show that the designed ASA can receive PD signals with high SNR and can be used for partial discharge inception voltage (PDIV) tests on insulation systems/models according to the IEC 60034-18-41 and IEC 60034-27-5.","PeriodicalId":377544,"journal":{"name":"2018 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2018.8544893","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Partial discharge(PD) measurements under repetitive impulsive voltages should be performed on insulation systems of rotating machines fed by voltage converters for type and qualification tests according to International Electrotechnical Commission (IEC) standard. Compared with well-established PD test technologies at sinusoidal voltages, more issues should be considered when PD detection are carried out using repetitive impulsive voltages, because PD pulses coming from the samples and the disturbance coming from impulsive voltage generator often have similar features in both time and frequency domains. Among all PD measurement methods, ultra-high frequency (UHF) technologies are recommended to be used under repetitive impulsive voltage conditions because the UHF sensors with appropriate bandwidth can receive PD energy in high frequency range with high signal to noise ratio (SNR). However, when performing PD tests using UHF method at impulsive voltages, the test sensitivity depends largely on the performance of the antenna in frequency domain. This paper, therefore, aims to present a design of a novel Archimedes Spiral Antenna (ASA) specially used for PD tests at impulsive voltages. Through the electromagnetic simulation, the optimized parameters of the antenna are selected and discussed. The PD tests at repetitive impulsive voltages show that the designed ASA can receive PD signals with high SNR and can be used for partial discharge inception voltage (PDIV) tests on insulation systems/models according to the IEC 60034-18-41 and IEC 60034-27-5.
一种用于重复方波电压下PD测量的新型阿基米德螺旋天线
根据国际电工委员会(IEC)标准,应对由电压变换器供电的旋转机械绝缘系统进行重复脉冲电压下的局部放电(PD)测量,以进行型式和鉴定试验。与成熟的正弦电压下的局部放电测试技术相比,使用重复脉冲电压进行局部放电检测需要考虑更多的问题,因为来自样品的局部放电脉冲和来自脉冲电压发生器的干扰在时间和频率域上往往具有相似的特征。在所有局部放电测量方法中,建议在重复脉冲电压条件下使用超高频(UHF)技术,因为具有适当带宽的超高频传感器可以在高频率范围内以高信噪比接收局部放电能量。然而,在脉冲电压下使用UHF方法进行PD测试时,测试灵敏度很大程度上取决于天线在频域的性能。因此,本文旨在设计一种新型的阿基米德螺旋天线(ASA),专门用于脉冲电压下的PD测试。通过电磁仿真,对天线的优化参数进行了选择和讨论。重复脉冲电压下的局部放电测试表明,所设计的ASA可以接收高信噪比的局部放电信号,并可用于符合IEC 60034-18-41和IEC 60034-27-5的绝缘系统/型号的局部放电起始电压(PDIV)测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信