Robustness of a Perceptually Lossless Medical Image Coder: Interpolation

S. Chai, David Wu, D. Tan, Henry Wu, D. Tan, Hong Ren Wu
{"title":"Robustness of a Perceptually Lossless Medical Image Coder: Interpolation","authors":"S. Chai, David Wu, D. Tan, Henry Wu, D. Tan, Hong Ren Wu","doi":"10.1109/ISPACS.2006.364793","DOIUrl":null,"url":null,"abstract":"Perceptually lossless medical image coding is an alternative for compressing medical images. It provides a solution to the challenge of delivering clinically critical information in the shortest time possible. In this paper, an investigation of the robustness of the perceptually lossless image coder is carried out by applying bilinear, biquadratic and bicubic standard and centered B-spline interpolation filters. In order to evaluate the visual performance, a subjective assessment was conducted consisting of 30 medical images and 6 image processing experts. Here, the perceptually lossless medical image coder was compared to the state-of-the-art JPEG-LS compliant LOCO and NLOCO image coders. Current results have shown that overall, there were no perceivable differences of statistical significance when the medical images were enlarged by a factor of 2","PeriodicalId":178644,"journal":{"name":"2006 International Symposium on Intelligent Signal Processing and Communications","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 International Symposium on Intelligent Signal Processing and Communications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISPACS.2006.364793","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Perceptually lossless medical image coding is an alternative for compressing medical images. It provides a solution to the challenge of delivering clinically critical information in the shortest time possible. In this paper, an investigation of the robustness of the perceptually lossless image coder is carried out by applying bilinear, biquadratic and bicubic standard and centered B-spline interpolation filters. In order to evaluate the visual performance, a subjective assessment was conducted consisting of 30 medical images and 6 image processing experts. Here, the perceptually lossless medical image coder was compared to the state-of-the-art JPEG-LS compliant LOCO and NLOCO image coders. Current results have shown that overall, there were no perceivable differences of statistical significance when the medical images were enlarged by a factor of 2
感知无损医学图像编码器的鲁棒性:插值
感知无损医学图像编码是压缩医学图像的一种替代方法。它为在尽可能短的时间内提供临床关键信息的挑战提供了解决方案。本文通过应用双线性、双二次、双三次标准和中心b样条插值滤波器对感知无损图像编码器的鲁棒性进行了研究。为了对视觉性能进行评价,由30张医学图像和6名图像处理专家进行了主观评价。在这里,将感知无损的医学图像编码器与最先进的JPEG-LS兼容的LOCO和NLOCO图像编码器进行比较。目前的结果表明,总的来说,当医学图像放大2倍时,没有可感知的统计学意义差异
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信