PERENCANAAN PEMBANGUNAN GEDUNG BARU 3 LANTAI “TABEK MAINAN” DI JALAN M.YAMIN KELURAHAN AUR KUNING KECAMATAN AUR BIRUGO TIGO BALEH KOTA BUKITTINGGI

Shinta Andira, Deddy Kurniawan, Ana Susanti Yusman
{"title":"PERENCANAAN PEMBANGUNAN GEDUNG BARU 3 LANTAI “TABEK MAINAN” DI JALAN M.YAMIN KELURAHAN AUR KUNING KECAMATAN AUR BIRUGO TIGO BALEH KOTA BUKITTINGGI","authors":"Shinta Andira, Deddy Kurniawan, Ana Susanti Yusman","doi":"10.33559/err.v2i2.1714","DOIUrl":null,"url":null,"abstract":"The number of buildings that collapsed was caused by the ability of a structure that was not able to support the working load, causing significant loss of property and even life. Therefore, in planning the design of a building structure, it must be really full of accuracy, careful calculations and according to the requirements with reference to the Indonesian National Standard (Indonesian Loading Regulations for Buildings and Buildings SNI-2847-2019 and SNI-1726-2019). This study aims to plan the dimensions of structural elements, calculation of structural reinforcement. The structural element data used are the results of the preliminary design (Preliminary Design). The analysis is assisted by the SAP2000 Version 11 program with the selection of a network system structure system (Grid System). Based on the results of the Preliminary design calculation, data is obtained for the use of the superstructure of the 1st floor to the 3rd floor where the cross section of the main column is 40 x 50 cm, the terrace column is 30x30 cm, the main beam is 30x40 cm, and the joist is 20x30 cm. The planning of floor slabs and also not concrete which was carried out with Preliminary design was found to be 12 cm thick. Planning for the foundation using a well foundation with a depth of 2 meters, and using a concrete buis with a diameter of 1 meterKeywords: Preliminary design, SAP2000 analysis, reinforcement calculation, foundation bearing capacity","PeriodicalId":273539,"journal":{"name":"Ensiklopedia Research and Community Service Review","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ensiklopedia Research and Community Service Review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33559/err.v2i2.1714","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The number of buildings that collapsed was caused by the ability of a structure that was not able to support the working load, causing significant loss of property and even life. Therefore, in planning the design of a building structure, it must be really full of accuracy, careful calculations and according to the requirements with reference to the Indonesian National Standard (Indonesian Loading Regulations for Buildings and Buildings SNI-2847-2019 and SNI-1726-2019). This study aims to plan the dimensions of structural elements, calculation of structural reinforcement. The structural element data used are the results of the preliminary design (Preliminary Design). The analysis is assisted by the SAP2000 Version 11 program with the selection of a network system structure system (Grid System). Based on the results of the Preliminary design calculation, data is obtained for the use of the superstructure of the 1st floor to the 3rd floor where the cross section of the main column is 40 x 50 cm, the terrace column is 30x30 cm, the main beam is 30x40 cm, and the joist is 20x30 cm. The planning of floor slabs and also not concrete which was carried out with Preliminary design was found to be 12 cm thick. Planning for the foundation using a well foundation with a depth of 2 meters, and using a concrete buis with a diameter of 1 meterKeywords: Preliminary design, SAP2000 analysis, reinforcement calculation, foundation bearing capacity
倒塌的建筑物数量是由于结构的能力无法支撑工作负载,造成重大财产损失甚至生命损失。因此,在规划建筑结构设计时,必须真正做到充分准确,认真计算,并根据印度尼西亚国家标准(印度尼西亚建筑物和建筑物荷载规定SNI-2847-2019和SNI-1726-2019)的要求进行设计。本研究的目的是规划结构单元的尺寸,计算结构配筋。所使用的结构单元数据是初步设计(preliminary design)的结果。在SAP2000 Version 11程序的协助下,分析选择了一种网络系统结构系统(网格系统)。根据初步设计计算结果,获得了1层至3层上部结构的使用数据,其中主柱截面为40 × 50 cm,露台柱截面为30 × 30 cm,主梁截面为30 × 40 cm,托梁截面为20 × 30 cm。在初步设计中发现楼板的规划厚度为12厘米,而不是混凝土。基础规划采用井基础,井深2米,混凝土基础直径1米。关键词:初步设计,SAP2000分析,配筋计算,基础承载力
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信