DC Electric Arc Furnace Modelling for Power Quality Indices Assessment

A. Bracale, P. Caramia, P. D. Falco, G. Carpinelli, A. Russo
{"title":"DC Electric Arc Furnace Modelling for Power Quality Indices Assessment","authors":"A. Bracale, P. Caramia, P. D. Falco, G. Carpinelli, A. Russo","doi":"10.1109/ICHQP46026.2020.9177908","DOIUrl":null,"url":null,"abstract":"The operation of an Electric Arc Furnace (EAF) determines power quality disturbances in terms of voltage fluctuations and waveform distortions, due to the particular nature of the heating process and of the electric arc phenomenon. The analysis of DC EAFs and their induced power quality disturbances may be conveniently posed within a chaotic modeling framework. This paper presents a procedure for tuning the parameters of a chaotic model for the DC electrical arc. The procedure is based on a Simulink representation of the DC EAF installation and on the Chua’s model to represent the arc chaotic behaviour. The parameters of the Chua’s model are iteratively tested and optimized to minimize the errors in the evaluation of the spectral content of current waveforms at the point of common coupling. Data measured at the point of common coupling of an actual DC EAF are considered to carry out numerical simulations aimed at verifying the effectiveness of the proposed tuning procedure.","PeriodicalId":436720,"journal":{"name":"2020 19th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 19th International Conference on Harmonics and Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP46026.2020.9177908","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

The operation of an Electric Arc Furnace (EAF) determines power quality disturbances in terms of voltage fluctuations and waveform distortions, due to the particular nature of the heating process and of the electric arc phenomenon. The analysis of DC EAFs and their induced power quality disturbances may be conveniently posed within a chaotic modeling framework. This paper presents a procedure for tuning the parameters of a chaotic model for the DC electrical arc. The procedure is based on a Simulink representation of the DC EAF installation and on the Chua’s model to represent the arc chaotic behaviour. The parameters of the Chua’s model are iteratively tested and optimized to minimize the errors in the evaluation of the spectral content of current waveforms at the point of common coupling. Data measured at the point of common coupling of an actual DC EAF are considered to carry out numerical simulations aimed at verifying the effectiveness of the proposed tuning procedure.
直流电弧炉电能质量指标评价模型
由于加热过程和电弧现象的特殊性质,电弧炉(EAF)的运行决定了电压波动和波形畸变方面的电能质量扰动。对直流电弧炉及其引起的电能质量扰动的分析可以方便地在混沌建模框架内进行。本文提出了一种调整直流电弧混沌模型参数的方法。该程序基于直流电弧炉安装的Simulink表示和Chua模型来表示电弧混沌行为。蔡氏模型的参数进行了迭代测试和优化,以尽量减少在共耦合点电流波形频谱含量评估中的误差。在实际直流电弧炉的公共耦合点测量的数据进行了数值模拟,旨在验证所提出的调谐过程的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信