{"title":"Phase Shift Control of a Three-Phase Inverter for Balanced Secondary Currents in Misaligned Three-Phase Inductive Power Transfer Systems","authors":"J. Pries, G. Su, V. Galigekere, O. Onar","doi":"10.1109/WoW47795.2020.9291271","DOIUrl":null,"url":null,"abstract":"This paper presents a strategy for generating fundamental reference voltage commands for a double-sided LCC tuned three-phase wireless power transfer (WPT) system to achieve balanced output currents when the receiver and transmitter are not perfectly aligned. Formulas for translating the normalized fundamental current commands into phase-shift commands for two of the phase legs in a two-level three-phase inverter are derived. The methodology is validated through circuit simulations performed using coupler models derived from finite-element simulations. Simulation results for a 1.5 k W system design are included, which indicate near perfect correction of imbalance in the secondary currents for a typical misalignment case.","PeriodicalId":192132,"journal":{"name":"2020 IEEE PELS Workshop on Emerging Technologies: Wireless Power Transfer (WoW)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE PELS Workshop on Emerging Technologies: Wireless Power Transfer (WoW)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/WoW47795.2020.9291271","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
This paper presents a strategy for generating fundamental reference voltage commands for a double-sided LCC tuned three-phase wireless power transfer (WPT) system to achieve balanced output currents when the receiver and transmitter are not perfectly aligned. Formulas for translating the normalized fundamental current commands into phase-shift commands for two of the phase legs in a two-level three-phase inverter are derived. The methodology is validated through circuit simulations performed using coupler models derived from finite-element simulations. Simulation results for a 1.5 k W system design are included, which indicate near perfect correction of imbalance in the secondary currents for a typical misalignment case.
本文提出了一种用于双面LCC调谐三相无线电力传输(WPT)系统的基本参考电压命令生成策略,以在接收机和发射机不完全对准时实现输出电流平衡。导出了将两电平三相逆变器中两个相支路的归一化基波电流命令转换为相移命令的公式。该方法通过使用从有限元仿真中导出的耦合器模型进行电路仿真来验证。文中给出了一个1.5 k W系统设计的仿真结果,表明在典型的不对准情况下,二次电流的不平衡得到了近乎完美的校正。