{"title":"Ion temperature in the Reversatron II RFP","authors":"P. Green, S. Robertson","doi":"10.1109/PLASMA.1989.166070","DOIUrl":null,"url":null,"abstract":"A seven-channel, f14 polychrometer with UV quartz optics has been constructed for ion temperature measurements on the Reversatron II RFP (R/a=50 cm/8 cm). The spectrometer has a focal length of 1.1 m and utilizes an 1800-line/mm grating. The spectrum is spread over a linear array of photomultiplier tubes by a 2-mm-diameter quartz cylinder lens. Resolution is below 0.1 AA, and channel separation is 0.4 AA. Initial measurements have been made in 25-kA helium discharges with no conducting shell surrounding the resistive vacuum chamber. The He I line at 3888 AA, which is predominantly from the plasma edge, indicates T/sub i/ approximately=8 eV. The He II line at 4685 AA, which is less weighted by the edge, indicates T/sub i/ approximately=17 eV. A search is being made for impurity lines that are indicative of the central region of the discharge. Similar measurements will be made with other boundary conditions.<<ETX>>","PeriodicalId":165717,"journal":{"name":"IEEE 1989 International Conference on Plasma Science","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1989-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE 1989 International Conference on Plasma Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PLASMA.1989.166070","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A seven-channel, f14 polychrometer with UV quartz optics has been constructed for ion temperature measurements on the Reversatron II RFP (R/a=50 cm/8 cm). The spectrometer has a focal length of 1.1 m and utilizes an 1800-line/mm grating. The spectrum is spread over a linear array of photomultiplier tubes by a 2-mm-diameter quartz cylinder lens. Resolution is below 0.1 AA, and channel separation is 0.4 AA. Initial measurements have been made in 25-kA helium discharges with no conducting shell surrounding the resistive vacuum chamber. The He I line at 3888 AA, which is predominantly from the plasma edge, indicates T/sub i/ approximately=8 eV. The He II line at 4685 AA, which is less weighted by the edge, indicates T/sub i/ approximately=17 eV. A search is being made for impurity lines that are indicative of the central region of the discharge. Similar measurements will be made with other boundary conditions.<>