{"title":"A novel AGC simulation scheme based on reduced order prime mover models","authors":"K. Divya, P. N. Nagendra Rao","doi":"10.1109/TENCON.2003.1273417","DOIUrl":null,"url":null,"abstract":"This paper presents a new simulation scheme for AGC studies of power system. The proposed scheme uses a different set of assumptions from that conventionally used. In this scheme, all the areas have been considered to be operating at the same frequency. Further, the proposed approach can preserve the identity of each generating unit. Additionally, the computational complexity has been reduced by resorting to lower order generating unit models. In this context, model order reduction techniques have been used to obtain lower order models for AGC studies. The effectiveness of the new simulation approach is demonstrated by considering the IEEE 30 bus test system as a 3 area system.","PeriodicalId":405847,"journal":{"name":"TENCON 2003. Conference on Convergent Technologies for Asia-Pacific Region","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"TENCON 2003. Conference on Convergent Technologies for Asia-Pacific Region","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TENCON.2003.1273417","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

This paper presents a new simulation scheme for AGC studies of power system. The proposed scheme uses a different set of assumptions from that conventionally used. In this scheme, all the areas have been considered to be operating at the same frequency. Further, the proposed approach can preserve the identity of each generating unit. Additionally, the computational complexity has been reduced by resorting to lower order generating unit models. In this context, model order reduction techniques have been used to obtain lower order models for AGC studies. The effectiveness of the new simulation approach is demonstrated by considering the IEEE 30 bus test system as a 3 area system.
一种基于降阶原动机模型的AGC仿真方法
本文提出了一种新的电力系统AGC仿真方案。提议的方案使用了一组不同于常规使用的假设。在这个方案中,所有的区域都被认为以相同的频率运行。此外,该方法可以保持每个发电机组的身份。此外,通过采用低阶发电单元模型降低了计算复杂度。在这种情况下,模型降阶技术已被用于获得AGC研究的低阶模型。将ieee30总线测试系统作为一个三区系统,验证了该仿真方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信